Installation: Open the SIM card cover on the back side of RTU5024,insert your SIM Card.
Reset the password: Press and hold the RESET button(closed to the SIM card holder), then power ON,after
3 seconds later,MCU LED will start to flash 5 times, the RTU5024 will only reset password to 1234. This
operation will reset the password to default 1234 and other parameters, but the authorized users numbers will
remain on the memory.
And if still hold the button for more than 10 seconds until the LED start to flash again and then release the
button,that will reset device working parameters and delete all authorized numbers and TEL number.
( For V2017 controller. No inside battery and switch )
5.0 Auto clock adjust with received SMS (This is necessary if need to use the
time-authorization enablement number):
Send
pwdTELphone number of the RTU5024#
to the RTU5024 for adjust the device clock.
E.g.: 1234TEL00861351015# if the SIM card number inside the RTU5024 is 00861351015.
RTU5024 Reply: TEL I
S 00861351015
Then later every time after powered on,device will send an SMS to it self to adjust the clock
5.1 Change Password
1234Pnew password
E.g.: 1234P6666 for change the new password to 6666.
RTU5024 return: “Password changed to“new password”, please remember it carefully.”if sucessfully.
5.2 Authorized number managerment
5.2.0 Add authorized number:
pwdAserial number#authorized number#start time#end time#
A:command code.
serial number: the authorized number’s position, from 001~200.
start time:yy(year)mm(month)dd(day)hh(hour)mm(minute).the start time of this number can call in to control.
end time: yy(year)mm(month)dd(day)hh(hour)mm(minute).the end time of this number can call in to control.
Without start time and end time means: Always can call in to control.
E.g.: 1234A003#123456# to set the phon
e no.123456 at the 3
rd
position and always can call in to control.
E.g.: 1234A016#123456#1502050800#1502051000# to set the phone number 123456 at the 16
th
position,
t
his number can call in to control during Feb 5
th
8:00a.m.(1502050800) to Feb 5
th
10:00a.m.(1502051000).
Note: 1. The authorized number means the one who can dial the RTU5024 to control the relay.
2. The Serial Number is the position to store the authorized users, from 001~1000.