DAILY OPERATION
The hopper and furnace top will be hot during operation; therefore, you should always use some type of
hand protection when refueling your furnace.
Never place your hand near the auger while the furnace is in operation.
In the event of a power outage, the furnace WILL NOT function. It is very important that unit be vented properly, as the
natural draft is needed to clear the smoke from the furnace during a power outage. In case of power outage, remove any

If the unit was “ON” when the power outage occurred, one of the following will take place when power is restored:

will have to press the “OFF” button and then the “ON” button again to begin a new start-up sequence.
If the furnace has cooled-off, it will reset to its “OFF” condition. At this point, you may press the “ON” button to
begin a new start-up sequence.
NOTE: The unit will also shut down in the event of an draft fan failure; if this is the case, the unit will not re-start and you
must contact Customer Service at (800) 750-2723.
SAFETY AND CONVENIENCE FEATURES
Your King incorporates a safety pressure switch that helps ensure proper operating conditions before feeding fuel to
the burn pot. Because the furnace works using an induced draft pressure, the furnace will not continue to operate if the
viewing door is left open, if the draft fan fails or if the exhaust system is blocked.
The temperature limit control will prevent your furnace from operating at abnormally high temperatures. Should the
furnace temperature begin to approach the factory pre-set limit, the temperature limit control will automatically slow down
the auger feed rate until the temperature returns to a normal condition. Both room air fans will also operate at full speed
until the furnace returns to normal operating temperatures.

lower setting.
1.)
2.)
Ì
Ì
Ì Failure to clean and maintain this unit as indicated can result in poor performance and safety hazards.
Ì 
inspection, cleaning, or maintenance work.
Ì Never perform any inspections, cleaning, or maintenance on a hot furnace.
Ì 
Ì 
Ì 
EXHAUST SYSTEM
    

furnace can lead to soot formation which will collect in the exhaust system. Therefore, it is important that the exhaust
system be inspected and cleaned at least monthly during the burning season. Be aware
less creosote is deposited, and that weekly cleaning can be necessary in mild weather, even though monthly cleanings
can be enough in the coldest months.
Check the clean out tees periodically to determine the required cleaning schedule. 3 or 4-inch chimney brushes are
available for chimney cleaning. If the exhaust system or outside air pipes have screens on them, frequently clean the

LIGHTING INSTRUCTIONS
CAUTION: DO NOT USE CHEMICALS OR FLUIDS TO START THE FIRE



area. 

increase the heat setting as well as the draft fan speed. After 3 minutes, the auger and agitator will start rotating. Note:
The room fans will not operate until your furnace reaches preset operating temperatures. If proper operation of your

Turn the Heater 



 
 
 
approximately 1 inch. This will automatically match your feed rate with the proper combustion air. As you increase the
heat setting, your feed rate and combustion air increase together. Once the unit reaches operating temperature, you
may reduce the heat setting.
 




the auger to run continuously until you release the button.
 Once the fuel starts burning aggressively, you can adjust the heat setting to your desired range. Make sure that you
pull the damper out approximately 1 inch. It may need to be pulled out more for higher heat settings. Try opening a
1/4 inch at a time.
 As you begin to have better understanding of how the heater operates and the amount of heat you require, you can
adjust the heat settings up or down to your satisfaction.
 

 

SHUT-DOWN PROCEDURE
Press the “OFF” button on the control panel to put the furnace in shut down mode. At this time, the red light above the

continue to operate. When the internal temperature of the unit drops below the factory preset temperatures, the room
air fans and draft fan will cease to operate. The red light will then shut off and the unit will be completely shut down.
Never shut down this unit by unplugging it from the power source. Doing so can cause damage to the appliance or cause

If the furnace stays on for more than 2 hours after pressing the “OFF” 
out, the furnace can be unplugged from the outlet. After approximately 10 seconds, the unit can be re-connected to the
power source and the control board will be reset.
WARNING: Never shut down this unit by unplugging it from the power source.
START-UP PROCEDURE