5. Prepare a solution of an appropriate product for the cleaning of ice machines (lime). Do not use hydrochloric acid. We
recommend the use of any
NSF approved scale removal product prepared according to the manufacturer’s instructions.
6. Fill water tray with the solution.
7. Switch on the machine while keeping pressed the wash button behind the front grid in order to run water pump. Let solution
stand for 30-40 mi
nutes and then switch off the machine.
8. Disconnect power and water supplies.
9. Remove the auxiliary pipe to drain and purge out the ice machine scale remover and residue. Replace it.
10. Mix enough cleaning solution (as in point 5) to clean parts and interior food zone surfaces.
11. Remove shield.