14
User Troubleshooting Guide
UNDERCOUNTER MODELS:
None of the electrical parts work.
The machine is unplugged.
Plug in the machine and
verify shocket power.
Curtain not properly
closed.
Check no ice and it moves freely.
Inlet strain at water valve blocked.
Ice slab empty or too thick.
Difficult to release ice slab at harvest.
Unit bad leveled (tilted to back).
Not uniform flow pattern at evaporator.
Dirty or scaled distributor.
Perform descaling procedure.
Remove and clean distributor (pull
from two clips at distributor sides).
Unit run and stops alternatively itself.
Clean air condenser (behind front grid).
or further problems call aftersales service.
MODULAR MODELS:
None of the electrical parts work.
The machine is unplugged.
Plug in the machine and
verify shocket power.
Front switch position
“0”.
Move to “ICE” (behind front panel).
Inlet strain at water valve blocked.
All the electrical parts work but not
compressor. (water doesn’t get frozen).
Front switch position
“WASH”.
Move to “ICE” (behind front
panel).
Not enough water to end cycle.
Water level probe too low.
Move up (Steel rod beside pump).
Defective drain valve
(check drain leak during ice stage).
Level probe to high or scaled.
Ice slab empty or too thick.
Desadjusted/scaled thickness probe.
Difficult to release ice slab at harvest.
Unit bad leveled (tilted to back).
Not uniform flow pattern at evaporator.
Dirty or scaled distributor.
Perform descaling procedure.
Remove and clean distributor (pull from
two clips at distributor sides).
Clean (check algo incoming water/air
tempetature).
Unit stops after few time running.
Clean air condenser (back).
or further problems call aftersales service.