6
Made in Greece.
The device is under two year’s guarantee. The guarantee is valid only if the manual instructions have been applied. The control and service of the device must be done by an authorized technician. The guarantee covers only the replacement or the service of the device. KIOUR PC
implements a Quality Management System according to EN ISO 9001:2015 Standard with registration number 01013192. KIOUR preserves the right to adjust its products without further notice.
Sensor type NTC/PTC
0 = PTC
1 = NTC
Response time of the device on network
Device address on network
Display’s indication
0 = room temperature indication
1 = SET POINT (SΡo) indication unless an alarm appears. The
first time that the cabinet turns on, room’s temperature is displayed
until the cabinet reaches for the first time SPo. Afterwards SPo is
constantly displayed regardless of room temperature.
Door switch operation
0 = OFF
1 = NO (normally open)
2 = NC (normally close)
If the cabinet’s door remains open for 2 minutes, the alarm dor is
activated and the compressor stops.
cabinet’s program is displayed (industrial factory settings) – the
parameter cannot be programmed
Baud rate:
0 = 2400 / 1 = 4800 / 2 = 9600 / 3 = 19200
Enter the new value, exit the parameters menu by pressing
and toggle power supply of the device.
Product number – not programmable
Firmware version - no access
Evaporator sensor malfunction
Open door (
If the cabinet’s door remains open for 2 minutes, the alarm dor is activated and the compressor stops)
error in memory RAM: re-enter the SPo of the cabinet (see ADJUSTING ROOM’S TEMPERATURE – SET POINT page 1)
The alarms are automatically deactivated once the cause of the alarm disappears.