WUXI KIPOR POWER CO., LTD.
GENERATOR
R
Single-phase:
KDE12EA
KDE12STA
Three-phase:
KDE12EA3
KDE12STA3
Question and Answer IconNeed help?

Do you have a question about the Kipor KDE12STA3 and is the answer not in the manual?

Kipor KDE12STA3 Specifications

General IconGeneral
Rated Frequency (Hz)50
Fuel Tank Capacity25 L
Noise Level dB(A)@7m72
Noise Level72 dB(A)@7m
Starting SystemElectric start
Rated Voltage (V)230
Engine Type4-stroke, single cylinder, air-cooled

Summary

Preface and Safety Information

General Warnings

Important safety warnings regarding generator operation, moving parts, and flammability.

General Cautions

Precautions for operation, maintenance, and user safety, including oil type and keeping children away.

1. Main Technical Specifications and Data

Digital panel electric system

Troubleshooting Common Panel Faults

Diagnosing and resolving faults related to the digital panel, including no display or abnormal signals.

Troubleshooting Generator Voltage Issues

Voltage Not Right or No Voltage

Diagnosing issues with incorrect or absent voltage, including voltmeter and AVR faults.

Generator Fails to Reach Rated Voltage

Addressing problems where the generator speed or voltage is too low, or wiring issues.

3. SAFETY PRECAUTIONS FOR SERVICING

2. Judge and eliminate troubles

Engine Not Running Troubleshooting

Diagnosing issues when the engine does not run, including battery, starter, and fuel system problems.

5. STARTING-UP&RUNNING PROCEDURE

Generator Starting and Running Steps

Procedure for starting the generator, ensuring normal voltage, and running with load.

10. SIMPLIFIED TROUBLESHOOTING GUIDE

General Troubleshooting Precautions

General safety advice for troubleshooting, including warnings about rotating parts, electric shock, and hot surfaces.

8. Load

7. THE FUNCTIONS OF THE DIGITAL PANEL

Single-Phase Digital Panel Functions

Explanation of the digital panel display items and knob functions for single-phase generators.

Operating Trouble Code Map List

List of fault codes (P-01 to P-08) and their corresponding issues and indicators.

OUTPUT CURRENT INDICATING GENERATOR CURRENT

Three-Phase Digital Panel Functions

Explanation of digital panel indicators and functions for three-phase generators.

9. MALFUNCTION AND COUNTERMEASURES

Maintenance Schedule

Schedule for daily, 50, 250, 500, and 1000-hour checks and replacements.

6. STOP PROCEDURE

Related product manuals