EasyManua.ls Logo

KitchenAid KHDD 3020 - Injectors Table

KitchenAid KHDD 3020
16 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
14
Injectors table
COUNTRIES: BE - FR - CATEGORY II2E+3+
ELECTRICAL SUPPLY: 230 V ~ 50 Hz
Type of gas used
Ty p e o f
burner
Injector
marking
Primary air
adjustment
(X) (mm)
Rated
thermal flow
rate (kW)
Rated
consumption
Reduced heating capacity
(kW)
Gas pressure (mbar)
BE FR min. rat. max.
NATURAL GAS
(Methane)) G20
17 20 25
rapid 128 3,00 286 l/h 0,80 0,60
semi-rapid 95 1,65 157 l/h 0,45 0,35
LIQUEFIED
PETROLEUM GAS
(Butane) G30
20 28-30 35
rapid 87 3,00 218 g/h 0,60 0,60
semi-rapid 67 1,65 120 g/h 0,35 0,35
LIQUEFIED
PETROLEUM GAS
(Propane) G31
25 37 45
rapid 87 3,00 214 g/h 0,60 0,60
semi-rapid 67 1,65 118 g/h 0,35 0,35
Type of gas used Model configuration Nominal heating capacity (kW) Total rated consumption
Air necessary (m
3
) for the
combustion of 1 m
3
of gas
G20 20 mbar 2 burners 4,65 443 l/h 9,52
G30 28-30 mbar 2 burners 4,65 338 g/h 30,94
G31 37 mbar 2 burners 4,65 332 g/h 23,80
COUNTRIES: ES - GB - IT - CATEGORY II2H3+
ELECTRICAL SUPPLY: 230 V ~ 50 Hz
Type of gas used Type of burner
Injector
marking
Primary air
adjustment
(X) (mm)
Nominal
heating
capacity (kW)
Rated
consumption
Reduced
heating
capacity (kW)
Gas pressure (mbar)
min. rat. max.
NATURAL GAS
(Methane) G20
17 20 25
rapid 128 3,00 286 l/h 0,60
semi-rapid 95 1,65 157 l/h 0,35
LIQUEFIED PETROLEUM
GAS (Butane) G30
20 28-30 35
rapid 87 3,00 218 g/h 0,60
semi-rapid 67 1,65 120 g/h 0,35
LIQUEFIED PETROLEUM
GAS (Propane) G31
25 37 45
rapid 87 3,00 214 g/h 0,60
semi-rapid 67 1,65 118 g/h 0,35
Type of gas used Model configuration Nominal heating capacity (kW) Total rated consumption
Air necessary (m
3
) for the
combustion of 1 m
3
of gas
G20 20 mbar 2 burners 4,65 443 l/h 9,52
G30 28-30 mbar 2 burners 4,65 338 g/h 30,94
G31 37 mbar 2 burners 4,65 332 g/h 23,80