12
When heating over 200°C for the first time, an odour nuisance
may occur due to evaporation, this is not harmful to health.
Example first firing program:
60-100°C/h until 600°C, after that
skip (fast heating) until 1200°C,
60 min. dwell
During all programs the noise of the protectors in the power
box is clearly audible. After completion of the firing test
program your KITTEC
®
kiln is ready for use.
Attention!
NEVER open the hot kiln when the firing chamber
temperature > 50°C.
Always switch off the controller at the power switch if the kiln
is not in use. For a longer period out of use the electric power
plug should be disconnected at the main isolator switch.