64
EN
Power level
1 2 3 4 5
Screw
conveyor
motor
OFF
(1A):050
OFF
(2A):055
OFF
(3A):045
OFF
(4A):040
OFF
(5A):035
ON
(1B):015
ON
(2B):020
ON
(3B):020
ON
(4B):020
ON
(5B):020
Exhaust gas
motor
(1C):018 (2C):018 (3C):017 (4C):016 (5C):016
Ash
cleaning
period
(P23):000 (P27):010 (P31):015 (P35):020 (P39):030
Screw motor: Minimum adjustable value is 0.1 second. The adjustable value for OFF/
ON is 0-9.9 seconds. (1 A) 050, (1B) 015 means that the screw motor stops for 5.0
seconds and works for 1.5 seconds.
Exhaust engine: The adjustable value is 001-0035 (155-240 V). The draught decreases
as the number increases. 001 means the strongest draught, 035 means the weakest
draught.
Ash cleaning period: 000 means OFF, 060 is the highest value. P31:015 ] in the 3rd
power stage means that the exhaust engine runs at maximum power for 15 seconds
after 1 hour to remove the ash.
Note: The above parameters are for your information only, they change
whenthe caloric value of the pellet changes!
Overload protection
There is a fuse in the mains plug on the rear of the furnace to prevent
overvoltage and overcurrent. If the fuse burns out, have it replaced by a
specialist company with an equivalent standard fuse.