OPERATING INSTRUCTIONS
DATA HOLD
Data is held on the display for 15 seconds following the end of any
measurement event. HOLD
J
appears on the display.
AUTO POWER-OFF (APO)
At the end of any measurement event, the meter automatically powers off
after 15 seconds of inactivity.
BACKLIGHT
Press and hold the MODE button
1
to activate / deactivate the backlight.
STATISTICS
MIN / MAX / AVG /DIFF statistical parameters are specific to the current or
most recent measurement event. Following the end of measurement event,
before auto power-off occurs, subsequent presses of the MODE button
1
may be used to toggle through the parameters.
SETTINGS
Settings are accessed by pushing the SET button
2
when the meter is
in HOLD status. Subsequent pushes of the SET button toggle through the
various settings options. The settings menu may be exited at any time by
pulling the trigger
5
or by toggling through all available options.
EMISSIVITY: Emissivity may be set by using the UP/DOWN buttons
3
.
This setting is not available if the K-type probe is inserted into the meter
°F / °C: Press the MODE button
1
to switch between Fahrenheit and
Celcius temperature scales. The meter will remain in the scale selected
following power on/off cycles
HI: High temperature alarm. Press MODE
1
to turn on/off the high
temperature alarm. Use the UP/DOWN buttons
3
to set the temperature
threshold above which the user will be alerted
LO: Low temperature alarm. Press MODE
1
to turn on/off the low
temperature alarm. Use the UP/DOWN buttons
3
to set the temperature
threshold below which the user will be alerted
AUDIBLE ALARMS:
Press MODE
1
to turn on/off audible alerts for Hi/Lo
temperature alarms. Note the on/off indicator on the bottom left of the display.
When audible alarms are off the mute icon
C
will be visible in the display.
Visual alerts are always on and are indicated by flashing Hi/Lo icons on the
display when the measurement is above/below the temperature thresholds.
TRIG: Press MODE
1
to turn on/off the trig function. When trig is turned
on the meter will automatically APO if the trigger is held depressed for more
than 10mins when measuring using IR. This setting is not available if the
K-type probe is inserted into the meter.