Do you have a question about the Klein Tools NCVT-2P and is the answer not in the manual?
Activates Non-Contact Voltage Testing feature, performs self-test, and powers off the tester.
Follow instructions to ensure safe operation, preventing severe injury or death from electric shock.
Do not attempt to repair tester; avoid extremes in temperature or high humidity.
Choose between Mode 1 (70-1000V AC) and Mode 2 (12-1000V AC) using the power button.
Test on live circuit first, then place tip near voltage source for audible and visual indication.
Activate silent operation by pressing and holding the NCV Power-ON button for over 2 seconds.
Replace batteries when low-power LED blinks; unscrew cap, replace batteries, and tighten cap.
Clean with dry cloth; remove batteries for prolonged storage, avoid extreme temperatures/humidity.
Dispose of equipment and accessories according to local regulations; do not place in trash.
Activates Non-Contact Voltage Testing feature, performs self-test, and powers off the tester.
Follow instructions to ensure safe operation, preventing severe injury or death from electric shock.
Do not attempt to repair tester; avoid extremes in temperature or high humidity.
Choose between Mode 1 (70-1000V AC) and Mode 2 (12-1000V AC) using the power button.
Test on live circuit first, then place tip near voltage source for audible and visual indication.
Activate silent operation by pressing and holding the NCV Power-ON button for over 2 seconds.
Replace batteries when low-power LED blinks; unscrew cap, replace batteries, and tighten cap.
Clean with dry cloth; remove batteries for prolonged storage, avoid extreme temperatures/humidity.
Dispose of equipment and accessories according to local regulations; do not place in trash.
| Type | Non-Contact Voltage Tester |
|---|---|
| Detection Method | Non-Contact |
| Audible Alert | Yes |
| Visual Indicator | Yes |
| Battery Type | 2 x AAA |
| CAT Rating | CAT IV 1000V |
| Altitude | 2000 m |
| Power Source | Battery |
| Frequency | 50Hz - 60Hz |
| Operating Temperature | -10°C to 50°C |
| Safety Rating | CE |
| Features | Auto Power Off, Low Battery Indicator |
| Voltage Range | 12 to 1000V AC |
| Voltage Detection | AC |












Loading...