1. Activating the Battery. Move the
activation switch to the ACTIVATED
position. If necessary, you may use
a small tool to help activate switch
if needed. Once unit is activated, it
cannot be turned off, only
permanently deactivated. (Fig. 1 )
*NOTE: Alarm will beep and will
announce that it has been
activated, both audibly and
visually. Please follow those
directions.
2. Test the CO alarm by pressing the
“Test/Reset” button.
3. This alarm can be mounted to a
wall or can be used with the
included stand to rest on a
tabletop – see “INSTALLATION OF
ALARM BRACKET AND DESK
STAND” for additional details.
4. To minimize the risk of permanent
damage, this alarm should not be
mounted to the wall or rest on a
surface which is higher than 6
feet (1.8 meters) from the floor.
CARBON MONOXIDE CANNOT
BE SEEN OR SMELLED BUT CAN
KILL YOU. IF ALARM SIGNAL
SOUNDS: 1. OPERATE TEST/SILENCE
BUTTON. 2. CALL YOUR EMERGENCY
SERVICES (FIRE DEPARTMENT OR
911). 3. IMMEDIATELY MOVE TO
FRESH AIR -OUTDOORS OR BY AN
OPEN DOOR/ WINDOW.
MAINTENANCE AND TESTING:
ALARM IS SEALED, WITH NO
SERVICEABLE PARTS.
BATTERY IS NOT REPLACEABLE.
CONSTANT USE AT HIGH OR LOW
TEMPERATURES OR HIGH
HUMIDITY MAY REDUCE
BATTERY LIFE. TEST
WEEKLY.
GENTLY VACUUM
MONTHLY. TEN YEARS
AFTER INITIAL POWER UP,
THIS UNIT WILL “BEEP”
TWICE EVERY 30
SECONDS, AND “END OF
LIFE - REPLACE UNIT”
WILL APPEAR ON THE
DISPLAY, INDICATING IT IS
TIME TO REPLACE
THE UNIT.
REPLACE IMMEDIATELY! IT
WILL NOT DETECT CO IN THIS
CONDITION.
TO ORDER REPLACEMENT
USERS MANUAL OR TO
RETURN ALARM CALL
CONSUMER AFFAIRS:
1-800-XXX-XXXX
www.knox.com
Manufactured in Mexico
MODEL NO. 7000
SINGLE STATION CO ALARM
KNOX COMPANY, 1601 W. DEER VALLEY RD.
PHOENIX, AZ 85027
WARNING!
3055574
HOW TO ACTIVATE ALARM:
1) TO ACTIVATE ALARM, MOVE
SWITCH BELOW TO THE
“ACTIVATED” POSITION.
2) LISTEN FOR ACTIVATION
MESSAGE.
3) TO ENSURE ALARM IS
ACTIVATED, PRESS
“TEST/RESET” BUTTON AND
LISTEN FOR TEST MESSAGE.
HOW TO DEACTIVATE ALARM:
1) TO DEACTIVATE ALARM, USE A
SCREWDRIVER TO BREAK THE
TAB BEHIND THE CROSS-
HATCHED AREA ABOVE, AND
MOVE THE SWITCH TO THE
DEACTIVATE POSITION.
2) LISTEN FOR DEACTIVATION
MESSAGE.
3) ONCE DEACTIVATED, THE
ALARM CANNOT BE REACTIVATED, OR
RE-ATTACHED TO MOUNTING PLATE.
REPLACE IMMEDIATELY. IT WILL NOT
DETECT CO IN THIS CONDITION.
ALARM GUIDE:
Audio Alerts
4 “BEEPS” – CO ALARM
2 “BEEPS” Every
30 Seconds – End of
Life/Replace
1 “BEEP” Every
30 Seconds – Error/Replace
ALARM RESPONSE
TIMES:
70 ppm CO Concentration
60-240 minutes
150 ppm CO Concentration
10-50 minutes
400 ppm CO Concentration
4-15 minutes
DEACTIVATED
ACTIVATED
BREAK TAB TO
DEACTIVATE
Conforms to UL STD 2034
Certied to CSA STD 6.19
Back of Unit
CARBON MONOXIDE CANNOT
BE SEEN OR SMELLED BUT CAN
KILL YOU. IF ALARM SIGNAL
SOUNDS: 1. OPERATE TEST/SILENCE
BUTTON. 2. CALL YOUR EMERGENCY
SERVICES (FIRE DEPARTMENT OR
911). 3. IMMEDIATELY MOVE TO
FRESH AIR -OUTDOORS OR BY AN
OPEN DOOR/ WINDOW.
MAINTENANCE AND TESTING:
ALARM IS SEALED, WITH NO
SERVICEABLE PARTS.
BATTERY IS NOT REPLACEABLE.
CONSTANT USE AT HIGH OR LOW
TEMPERATURES OR HIGH
HUMIDITY MAY REDUCE
BATTERY LIFE. TEST
WEEKLY.
GENTLY VACUUM
MONTHLY. TEN YEARS
AFTER INITIAL POWER UP,
THIS UNIT WILL “BEEP”
TWICE EVERY 30
SECONDS, AND “END OF
LIFE - REPLACE UNIT”
WILL APPEAR ON THE
DISPLAY, INDICATING IT IS
TIME TO REPLACE
THE UNIT.
REPLACE IMMEDIATELY! IT
WILL NOT DETECT CO IN THIS
CONDITION.
TO ORDER REPLACEMENT
USERS MANUAL OR TO
RETURN ALARM CALL
CONSUMER AFFAIRS:
1-800-XXX-XXXX
www.knox.com
Manufactured in Mexico
MODEL NO. 7000
SINGLE STATION CO ALARM
KNOX COMPANY, 1601 W. DEER VALLEY RD.
PHOENIX, AZ 85027
WARNING!
3055574
HOW TO ACTIVATE ALARM:
1) TO ACTIVATE ALARM, MOVE
SWITCH BELOW TO THE
“ACTIVATED” POSITION.
2) LISTEN FOR ACTIVATION
MESSAGE.
3) TO ENSURE ALARM IS
ACTIVATED, PRESS
“TEST/RESET” BUTTON AND
LISTEN FOR TEST MESSAGE.
HOW TO DEACTIVATE ALARM:
1) TO DEACTIVATE ALARM, USE A
SCREWDRIVER TO BREAK THE
TAB BEHIND THE CROSS-
HATCHED AREA ABOVE, AND
MOVE THE SWITCH TO THE
DEACTIVATE POSITION.
2) LISTEN FOR DEACTIVATION
MESSAGE.
3) ONCE DEACTIVATED, THE
ALARM CANNOT BE REACTIVATED, OR
RE-ATTACHED TO MOUNTING PLATE.
REPLACE IMMEDIATELY. IT WILL NOT
DETECT CO IN THIS CONDITION.
ALARM GUIDE:
Audio Alerts
4 “BEEPS” – CO ALARM
2 “BEEPS” Every
30 Seconds – End of
Life/Replace
1 “BEEP” Every
30 Seconds – Error/Replace
ALARM RESPONSE
TIMES:
70 ppm CO Concentration
60-240 minutes
150 ppm CO Concentration
10-50 minutes
400 ppm CO Concentration
4-15 minutes
DEACTIVATED
ACTIVATED
BREAK TAB TO
DEACTIVATE
Conforms to UL STD 2034
Certied to CSA STD 6.19
Fig. 1 Slide to activate.
Fig. 2 Break tab.
Slide to deactivate.
CARBON MONOXIDE CANNOT
BE SEEN OR SMELLED BUT CAN
KILL YOU. IF ALARM SIGNAL
SOUNDS: 1. OPERATE TEST/SILENCE
BUTTON. 2. CALL YOUR EMERGENCY
SERVICES (FIRE DEPARTMENT OR
911). 3. IMMEDIATELY MOVE TO
FRESH AIR -OUTDOORS OR BY AN
OPEN DOOR/ WINDOW.
MAINTENANCE AND TESTING:
ALARM IS SEALED, WITH NO
SERVICEABLE PARTS.
BATTERY IS NOT REPLACEABLE.
CONSTANT USE AT HIGH OR LOW
TEMPERATURES OR HIGH
HUMIDITY MAY REDUCE
BATTERY LIFE. TEST
WEEKLY.
GENTLY VACUUM
MONTHLY. TEN YEARS
AFTER INITIAL POWER UP,
THIS UNIT WILL “BEEP”
TWICE EVERY 30
SECONDS, AND “END OF
LIFE - REPLACE UNIT”
WILL APPEAR ON THE
DISPLAY, INDICATING IT IS
TIME TO REPLACE
THE UNIT.
REPLACE IMMEDIATELY! IT
WILL NOT DETECT CO IN THIS
CONDITION.
TO ORDER REPLACEMENT
USER’S MANUAL OR TO
RETURN ALARM CALL
CONSUMER AFFAIRS:
www.knox.com/safety
Manufactured in Mexico
MODEL NO. 7000
SINGLE STATION CO ALARM
KNOX SAFETY,
1601 W. DEER VALLEY RD.
PHOENIX, AZ 85027
WARNING!
HOW TO ACTIVATE ALARM:
1) TO ACTIVATE ALARM, MOVE
SWITCH BELOW TO THE
“ACTIVATED” POSITION.
2) LISTEN FOR ACTIVATION
MESSAGE.
3) TO ENSURE ALARM IS
ACTIVATED, PRESS
“TEST/RESET” BUTTON AND
LISTEN FOR TEST MESSAGE.
HOW TO DEACTIVATE ALARM:
1) TO DEACTIVATE ALARM, USE A
SCREWDRIVER TO BREAK THE
TAB BEHIND THE CROSS-
HATCHED AREA ABOVE, AND
MOVE THE SWITCH TO THE
DEACTIVATE POSITION.
2) LISTEN FOR DEACTIVATION
MESSAGE.
3) ONCE DEACTIVATED, THE
ALARM CANNOT BE REACTIVATED, OR
RE-ATTACHED TO MOUNTING PLATE.
REPLACE IMMEDIATELY. IT WILL NOT
DETECT CO IN THIS CONDITION.
ALARM GUIDE:
Audio Alerts
4 “BEEPS” – CO ALARM
2 “BEEPS” Every
30 Seconds – End of
Life/Replace
1 “BEEP” Every
30 Seconds – Error/Replace
ALARM RESPONSE TIMES:
70 ppm CO Concentration
60-240 minutes
150 ppm CO Concentration
10-50 minutes
400 ppm CO Concentration
4-15 minutes
DEACTIVATED
ACTIVATED
BREAK TAB TO
DEACTIVATE
LED OPERATION:
Green = Normal
Amber = Trouble
Red = Alarm
See User Guide for
more information
Conforms to STD UL2034
5020949
HOW TO PERMANENTLY DEACTIVATE THIS ALARM
*NOTE – DEACTIVATION IS PERMANENT, AND CANNOT BE REVERSED
This CO alarm contains a sealed-in, non-replaceable / non-removeable battery.
Once it reaches the end of its service life, or after 10 years, whichever comes
first, the unit will alert you that it needs to be replaced, and you will need to
install a new CO alarm.
5. You can permanently deactivate the unit by using a tool to break the tab
underneath the cross-hatched area and moving the activation switch
to the DEACTIVATED position. (Fig. 2)
HOW TO INSTALL THIS ALARM - MODEL 7000
*NOTE – READ “WHERE TO INSTALL YOUR CO ALARM” PRIOR
TO INSTALLATION
Prior to installation, find the pair of self-adhesive labels included with this CO
alarm. On each label write in the phone number of your emergency responder
(e.g., 911) and a qualified appliance technician. Place one label near the CO
alarm, and the other label in the "fresh air" location you plan to go if the
alarm sounds.
*NOTE: ACTIVATE ALARM PRIOR TO ATTACHING MOUNTING BRACKET
8