TP-5592 7/96 Scheduled Maintenance 3-5
Service Schedule (Continued)
Perform Service at Intervals Indicated (X)
Before
Starting
After
50 Hrs./
1 Month
Every
100 Hrs./
3 Months
Every
300 Hrs./
6 Months
Every
500 Hrs./
Yearly
REMOTE CONTROL SYSTEM, etc.
Check compartment condition
(fuel, oil, or water leaks)
X
Test run generator set
X
(Monthly)
Check remote control operation
X
(Break-in
period)
X
EXHAUST SYSTEM
Inspect exhaust system components for
cracks and corrosion (exhaust line, hose clamps,
silencer, and outlet flapper) *&
X
Check that exhaust outlet is clear X
Check that hose clamps are tight X
Check for hose leaks X
Inspect the complete exhaust system *** X
GENERATOR
Blow dust out of generator *& X
* Requires removal of sound shield (if installed).
*** Should be performed by the Coast Guard Auxiliary.
# Reference engine service manual for procedure.
& Read WARNING found at the beginning of Section 3 regarding moving parts.