TP-5592 7/965-4 Wiring Diagrams
Voltage Reconnection (12-lead)
This reconnection procedure details voltage
reconnections only. If the generator set requires
frequency changes, the governor and voltage regulator
will need adjustment. See the generator service manual
for information regarding frequency adjustment.
The following information illustrates the reconnection of
12-lead generator sets In all cases, follow the National
Electrical Code (NEC) guidelines.
Reconnect the stator leads of the generator set if desiring
a different output phase or voltage. Refer to the following
procedure and the connection schematics following.
Followallsafetyprecautionsatthefrontofthismanualand
in the text during this procedure.
NOTE
Voltage reconnection! Affix notice togenerator setafter
reconnecting to a voltage different than the nameplate.
Ordervoltagereconnectiondecal246242fromauthorized
service distributors/dealers.
1. Move generator set master switch to OFF/RESET
position.
2. Disconnect engine starting battery, negative (--) lead
first. Disconnect power to battery charger (if
equipped).
3. Use Figure 5-4 to determine generator set voltage
configuration. Noteoriginalvoltageandreconnectas
needed.

Table of Contents

Other manuals for Kohler 20CCOZ

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kohler 20CCOZ and is the answer not in the manual?

Kohler 20CCOZ Specifications

General IconGeneral
BrandKohler
Model20CCOZ
CategoryInverter
LanguageEnglish

Related product manuals