Karen EnglishSep 12, 2025
What to do if my Kohler 21EKOZD Portable Generator breaker is not charged?
- TTracy AlvaradoSep 12, 2025
Verify that the motor operator is receiving voltage at the appropriate contacts, allowing it to wind the spring.
What to do if my Kohler 21EKOZD Portable Generator breaker is not charged?
Verify that the motor operator is receiving voltage at the appropriate contacts, allowing it to wind the spring.
How to address fuel filter restriction in my Kohler Portable Generator?
If the fuel filter of your Kohler Portable Generator is restricted, clean or replace the fuel filter. The cause is fuel filter restriction.
What to do if my Kohler 21EKOZD runs out of fuel or the fuel valve is off?
If your Kohler Portable Generator's fuel tank is empty or the fuel valve is shut off, add fuel and move the fuel valve to the ON position. This is because the fuel tank is either empty, or the fuel valve is shut off.
How to fix loose or corroded battery connections on a Kohler 21EKOZD?
If the battery connections of your Kohler Portable Generator are loose, corroded, or incorrect, verify that the battery connections are correct, clean, and tight. The cause of this problem is that the battery connections are loose, corroded, or incorrect.
What to do if my Kohler 21EKOZD bus sensing is not connected?
Verify that the bus sensing wiring is connected to the load side of the motor-operated breaker for this generator.
How to resolve breaker status feedback is not valid, no bus sensing in Kohler 21EKOZD Portable Generator?
Verify the wiring on the circuit breaker to ensure it is connected correctly. Verify bus wiring for all nodes. Verify the generator output is connected to the line side of the generator breaker.
What to do if the low oil pressure switch is inoperative on my Kohler 21EKOZD?
If the low oil pressure switch is inoperative on your Kohler Portable Generator, replace the low oil pressure switch and check the engine for damage. This is because the low oil pressure switch is inoperative.
What to do if the fuel injection timing is out of adjustment on my Kohler 21EKOZD?
If the fuel injection timing is out of adjustment on your Kohler Portable Generator, adjust the fuel injection timing. This is due to fuel injection timing being out of adjustment.
What to do if there is air in the fuel system of my Kohler 21EKOZD Portable Generator?
If there is air in the fuel system of your Kohler Portable Generator, bleed the diesel fuel system. The cause is air in the fuel system.
How to fix a faulty ground connection on my Kohler 21EKOZD Portable Generator?
If you find a faulty ground connection in your Kohler Portable Generator, clean and retighten the connection. The cause is a faulty ground connection.
Model | 21EKOZD |
---|---|
Type | Portable Generator |
Engine Displacement | 999 cc |
Fuel Type | Gasoline |
Voltage | 120/240V |
Frequency | 60 Hz |
Starting Method | Electric |
Dimensions | 48.5 in x 29.5 in |
Outlet Types | 1x 120/240V 50A |