Fig.4
4
B. Installation Check
1. Check AC power cable connection.
2. Check if AC power on.
3. Put outer cover back.
4. Insert security screws and tighten them.(Fig.4)
B.
1.
2.
3.
4. ( 4)
C. Test Running
C.
D. Operation Instructions
1. The machine starts operating automatically when user's
hands are put approximately 20cm (7.78") below the
sensor located next to air louver. Whenever the hands are
moved out of sensing range, the machine will stop after
approx. 0.5 sec.
2. The 0.2 sec time delay helps avoid false triggers by
unexpected movements.
3. For safety reasons, the machine will immediately stop
operating when it is used continuously over 45 seconds.
The machine resumes to standard function when hands
are moved away.
D.
1. 20cm
0.5
2. 0.2
3. 45
-5-
Steps
1. Shake
the
device
slightly.
1.
2. Check
power
voltage.
2.
3. Plug in. 3.
4. Put
hands
below the
device for
drying.
4.
Results
The device is firmly
fixed.
Use rated voltage.
Switch off external
power.
Air goes out at a
high speed.
Check the power if
the display light is
not on.
The device may be
burnt or cause
personal injury if not
running under rated
voltage.
There may be
abnormal sounds or
vibrations if the
device is not firmly
fixed.
Check if hands are
too far away from
the sensor if there is
no air going out.
Note