11.17
Section 11
Reassembly
11
Figure 11-52. Installing Cylinder Head Baf e.
5. Install the grommet around the high tension lead
(metal blower housings only). Insert the grommet
into the slot in the end of the blower housing.
Plastic blower housings have a formed slot to
contain the lead. Install the blower housing and
secure with the mounting screws. See Figures
11-53 and 11-54.
Figure 11-54. Installing Blower Housing.
6. Tighten all hardware securely when all sheet
metal pieces are in position.
Install Valve Cover and Muf er Bracket
RTV silicone sealant is used between the valve cover
and crankcase. Refer to page 2.1 for the approved
sealant.
NOTE: Always use fresh sealant. Using outdated
sealant can result in leakage.
1. Prepare the sealing surfaces of the cylinder head
and valve cover following Service Bulletin 252.
If it is a stamped steel valve cover, the atness
of the sealing surface must be checked prior to
reinstallation. See Section 10.
Figure 11-51. Installing Heat De ector and
Carburetor Side Baf e (not on all models).
4. Install the cylinder head baf e and secure with
the two hex. ange screws. Later production
models use one screw and one hex. ange nut.
See Figure 11-52.
Gasket
Heat De ector
Intake Studs
Silver Screw for
Ground Lead
Mounting Screws
Cylinder Head
Baf e
Hex. Flange
Screw or Nut
Figure 11-53. Installing Blower Housing.
Mounting Screws