8.22
Section 8
Electrical System and Components
Figure 8-24. Style "B" Commutator End Cap with
Brushes.
6. Install the thru bolts and tighten securely.
7. Lubricate the drive shaft with Kohler bendix
starter drive lubricant (Part No. 52 357 01-S).
Install the drive components following the
instructions for servicing the drive.
Figure 8-25. 110 Volt UL Approved Electric Starter.
110 Volt AC Starter
Some engines, on oor care equipment, are equipped with 110 volt, UL approved starters. See Figure 8-25.
These starters have no serviceable components. If the starter is damaged, worn, or faulty, the entire starter motor
must be replaced.
To
Starter
Push Button
Switch "Push" on
To 110 Volt AC Source