9.2
Section 9
Disassembly
Figure 9-1. Removing Spark Plug Lead, Oil Drains,
Oil Filter, and Oil Sentry
Switch (oil lter drain
plug not on all models).
Remove Muf er
1. Remove the hex. ange nuts from exhaust studs
and hex. ange screws from muf er bracket. See
Figures 9-2 and 9-3.
2. Remove the muf er and gasket from exhaust
outlet ange. Some engines may have an
additional heat de ector insert tube in the exhaust
port, behind the muf er ange. If present, remove
it also.
Figure 9-3. Removing Muf er.
Remove Retractable Starter
1. Remove the ve hex. ange screws and
retractable starter. See Figure 9-4.
Figure 9-4. Removing Retractable Starter.
Remove Electric Starter
Electric Starter (Bendix Drive or Solenoid Shift)
1. Disconnect the lead from the stud terminal on the
electric starter. See Figure 9-5. Disconnect both
leads on Solenoid Shift Starter.
2. Remove the two hex. ange screws and starter
assembly. Some bendix drive starters have
additional spacers between the mounting ange
and crankcase or under the head of the mounting
bolt. After noting their placement, remove and
retain the spacers.
Spark Plug
Lead
Oil Drain
Oil Filter
Optional Oil Sentry
Switch or
Oil Filter Drain Plug
Hex. Flange
Screws
Muf er
Muf er
Gasket
Hex. Flange Nuts
Figure 9-2. Removing Muf er.
Hex. Flange Screws (5)
Retractable
Starter
Muf er Bracket