1035530-X2-A 2 Kohler Co.
Tools and Materials
Thank You For Choosing Kohler Company
We appreciate your commitment to Kohler quality. Please take a few minutes to review this manual before you start
installation. If you encounter any installation or performance problems, please don’t hesitate to contact us. Our phone
numbers and website are listed on the back cover. Thanks again for choosing Kohler Company.
DANGER: Risk of electric shock. Disconnect power before servicing.
DANGER: Risk of electrical shock. For plug-in installations/wall-mounted electrical supply: Connect only
to a properly-grounded, grounding-type receptacle which is protected by a Ground-Fault Circuit-Interrupter
(GFCI). Do not remove the grounding pin or use a grounding adapter.
DANGER: Risk of electrical shock. For hardwire installations/through-floor electrical supply: Connect only
to a properly-grounded, dedicated 220 VAC, 15 A, 50 Hz circuit protected by a Class A Ground-Fault
Circuit-Interrupter (GFCI) or Earth-Leakage Circuit-Breaker (ELCB).
CAUTION: Risk of hazardous gases. If a new toilet is not installed immediately, temporarily place a rag in the
floor flange opening.
NOTICE: Follow all local plumbing and electrical codes.
NOTICE: Receptacles installed in bathrooms to be located at least 1 meter from a bathtub or shower if practical,
but in no case less than 0.5 meter.
Observe all local plumbing and building codes.
Carefully inspect the new toilet for damage.
Water and electrical supplies may installed through either the wall or the floor. For a more aesthetic look, installation
of the supplies through the floor is recommended.
There is a wiring schematic on the inside of the junction box cover.
Before You Begin