4. Install the Finished Wall
Install the Wall Material
Install the water-resistant wall board.
Cut out a 4 (10.2 cm) to 4-1/4 (10.8 cm) square at each tile
installation location.
Install the finished wall material.
5. Verify Depth and Install the Nipple
Remove the nipple.
NOTE: The minimum distance between the face of the tee/elbow
and the surface of the finished wall should be 2-1/4 (5.7 cm). The
measurement for typical installations is 2-3/4 (7 cm).
Measure the distance from the face of the tee/elbow to the
surface of the finished wall. Make any adjustments as needed.
If your measurement is 2-1/4 (5.7 cm): Use a close pipe nipple.
If your measurement is 2-3/4 (7 cm): Use a 1-1/2 pipe nipple.
Thread the nipple into the tee/elbow and hand tighten.
Measure the distance from the end of the nipple to the surface of
the finished wall. Verify that the distance is at least 1-1/2 (3.8
cm) and no more than 1-3/4 (4.4 cm).
Remove the nipple.
Apply thread sealant to the threads of the nipple.
Reinstall the nipple to the tee/elbow.
Run water through the system to flush out any dirt or debris.
4" (10.2 cm) –
4-1/4" (10.8 cm)
4" (10.2 cm) –
4-1/4" (10.8 cm)
4" (10.2 cm) –
4-1/4" (10.8 cm)
Cutout
Nipple
Tee (or Elbow)
Finished Wall
Cutout
2-1/4" (5.7 cm) Min
Kohler Co. 5 1043851-2-D