1
English rev 2.6
Platinum products
Service
Biowizard Platinum SF
Biowizard Platinum MF
Biowizard Platinum DEF
Biowizard Platinum XL MF
Cleanwizard Platinum CW-V

Questions and Answers

  • C
    Christopher DouglasAug 8, 2025
    What to do if Kojair Biowizard Platinum SF control system alarms for low air flow velocity?
    • D
      duartemichaelAug 8, 2025
      If the Kojair Laboratory Equipment control system alarms for low air flow velocity, you should check that grids on the workspace are not clogged. Also, ensure that a Bunsen burner is not used on the same side as the sensors inside the chamber (normally on the right side), as the flame can immediately trigger an alarm.
  • M
    Morgan PearsonAug 12, 2025
    What to do if my Kojair Biowizard Platinum SF alarm goes on, lights won’t go on and the fan is out of order?
    • M
      Michael ThomasAug 12, 2025
      If the alarm is activated, the lights won't turn on, and the fan isn't working on your Kojair Laboratory Equipment, verify that the power cable is properly connected both to the outlet and to the cabinet socket located on top of the cabinet. Also, check the user interface to ensure that the cabinet’s mode is set to normal.
  • M
    Misty ScottAug 17, 2025
    What to do if Kojair Biowizard Platinum SF Laboratory Equipment outlet is currentless?
    • L
      Luis NielsenAug 17, 2025
      If the outlet of your Kojair Laboratory Equipment is currentless, check if the fault current has tripped; the switch is located on the electrical box under the front panel. If the outlet is an accessory, ensure that the current supply is connected with a separate cable to the outlet behind the cabinet, placed on the installation channel.
  • J
    Jennifer SmithAug 23, 2025
    What to do if Kojair Biowizard Platinum SF control system alarms for low inflow air velocity?
    • K
      Kelly JohnsonAug 23, 2025
      If the Kojair Laboratory Equipment control system alarms for low inflow air velocity, verify that laboratory conditions meet the requirements. If the device is connected to an exhaust duct, confirm that the limit values set by the manufacturer correspond to the exhaust air values.
  • J
    Joe FlynnAug 28, 2025
    What to do if Kojair Biowizard Platinum SF Laboratory Equipment alarm goes on but no failure is found?
    • C
      chaddavisAug 28, 2025
      If the alarm goes on for your Kojair Laboratory Equipment, but no failure is found, check that the front window is at the height of the work opening.
  • A
    Alexandra SanfordSep 2, 2025
    Why is the air flow velocity not stable in Kojair Biowizard Platinum SF?
    • M
      Mary KellerSep 2, 2025
      To stabilize the airflow velocity in your Kojair Laboratory Equipment, ensure that cool air is not entering the cabinet through the front opening.

Summary

Testing

Airflow Measurements

Procedures for measuring airflow rates using different methods like hotwire anemometer and balometer.

Downflow (hotwire anemometer)

Detailed procedure for measuring downflow velocity using a hotwire anemometer.

Downflow Acceptance Criterions

Criteria for acceptable downflow velocity measurements for product protection.

Inflow (using balometer)

Detailed procedure for measuring inflow velocity using a balometer.

Inflow Acceptance Criterions

Criteria for acceptable inflow air velocity at the front aperture.

Aerosol Challenge Test of Filters

Procedure for testing the integrity and seal of HEPA filters using aerosol.

Aerosol Challenge Test: SF, MF and CW-V Cabinets

Specific steps for performing aerosol challenge tests on SF, MF, and CW-V cabinets.

Aerosol Challenge Test: Exhaust Filters

Procedure for accessing and testing exhaust filters.

Aerosol Challenge Test: XL Cabinets

Specific steps for performing aerosol challenge tests on XL cabinets.

Maintenance

H2 O2 Decontamination

Procedure for decontaminating the safety cabinet using hydrogen peroxide.

Changing Filters

General guidelines and procedures for replacing cabinet filters.

Changing Main Board

Procedure for replacing the main control board and restoring system functions.

Software Update

Update Core Version

Steps for updating the core processor firmware using programming tools.

Biocontrol Update

Procedure for updating the Biocontrol software on the display interface.

Update Biocontro i

Steps for updating the Biocontro i software component.

Update Main Version

Procedure for updating the main operating software version.

Technical Data

Spare Parts List

Circuit Diagrams

Trouble Shooting

Kojair Biowizard Platinum SF Specifications

General IconGeneral
CategoryLaboratory Equipment
TypeBiological Safety Cabinet
ClassClass II
Inflow Velocity0.45 m/s
LightingFluorescent
MaterialStainless Steel
UV LampOptional
CertificationEN 12469
FiltrationHEPA
Noise Level≤65 dB
Weight250 kg
Power Supply230V, 50Hz
Power Consumption600 W
Filter Efficiency99.995% @ 0.3μm
Construction MaterialStainless Steel

Related product manuals