Do you have a question about the koller ASZEP10-PL and is the answer not in the manual?
Crucial instruction to prevent filter damage from low water levels.
Ensures proper filter function and quiet operation.
Guidance on replacing the filter cartridge every three to four weeks.
Instructions for cleaning, unplugging, and avoiding detergents.
Warning about damaged cords and exposed wires; discard if damaged.
Advice on preventing water damage and electrical shorts.
Safety guidelines for children and individuals with reduced capabilities.
Recommendations for preventing wet plugs/receptacles and using GFCI outlets.
Information on how to contact customer service for warranty claims.
Details on excluded warranties and consequential damages.
This document describes an aquarium internal power filter, detailing its function, installation, maintenance, and safety instructions.
The aquarium internal power filter is designed to maintain clean and healthy water conditions in an aquarium. It operates by drawing water through a replaceable filter cartridge, which removes impurities and debris. The filtered water is then returned to the tank, ensuring continuous circulation and purification. The filter is equipped with a UL-approved pump motor, ensuring safe and reliable operation. Proper water level maintenance is crucial for the filter's quiet and efficient functioning, as operating below the minimum water level can cause damage. The filter is intended for household use and requires adult supervision for children under 13.
The filter comes with an adjustable hanger bracket for easy installation on the side of the tank. To install, the hanger bracket is placed at a 90-degree angle and aligned with one of the adjustment holes on the mounting post. It is then rotated until the hook is vertical. A "drip loop" should be created with the power cord to prevent water from dripping onto the electrical outlet, and using a GFCI outlet is recommended for added safety. Before initial use, the filter must be fully submerged in water until all air bubbles disappear. This ensures proper priming and prevents damage. Maintaining the water level between the recommended and maximum marks is essential for optimal performance and to prevent damage. The filter should never be operated below the minimum water level. When medicating fish, the filter cartridge should be removed as it can absorb medications.
Regular maintenance is key to the filter's longevity and effectiveness. The filter cartridge should be replaced every three to four weeks, or more frequently if it becomes heavily soiled or if the water flow diminishes. To change the cartridge, the internal filter must first be unplugged from the electrical outlet to stop water flow. The soiled cartridge is then removed, and a new cartridge is rinsed under running tap water before being placed into the filter. After replacing the cartridge, the filter can be plugged back into the electrical outlet. When cleaning the power filter, it is imperative to always unplug it from the electrical power source. Detergents or soap should not be used for cleaning, as their residues can be harmful to fish. The document also provides a QR code and a YouTube link to a video demonstrating how to clean the power filter, offering a visual guide for users. The filter uses specific replacement cartridges, Koller Products Filter Cartridges S (AQ10FC-30), which are widely available from online retailers.
Several important safety instructions are provided to ensure safe operation and prevent injury or damage. The unit should not be operated if the power cord or plug is damaged, as the power cord cannot be replaced. Users should inspect the power cord insulation for any cuts or exposed wires; if found, the unit should be discarded, and a new replacement motor ordered. Aquariums should never be placed on surfaces that can be damaged by water, as water can cause electrical shorts or damage fine surfaces. The appliance is not intended for use by individuals with reduced physical, sensory, or mental capabilities, including children under 13, without proper instruction and supervision from a responsible adult. Children under 13 must be supervised to ensure they do not play with the appliance. To prevent the unit's plug or receptacle from getting wet, the tank and stand should be positioned to one side of a wall-mounted receptacle, creating a "drip loop" with the power cord. The use of a GFCI outlet is also recommended for enhanced safety. The filter should never be operated unless fully submerged to the recommended water level, as this can cause damage to the filter.
| Model | ASZEP10-PL |
|---|---|
| Category | Water Filtration Systems |
| Operating Pressure | 40-80 PSI |
| Operating Temperature | 40-100°F |
| Type | Under Sink Reverse Osmosis System |
| Filtration Technology | Reverse Osmosis |
| Included Components | RO System, Storage Tank, Faucet, Installation Kit, Filters |
| Stages of Filtration | 5 Stages |
Loading...