UNIT INSTRUCTIONS
WITH IMPORTANT SAFEGUARDS
AND WARRANTY
UL Approved Pump Motor
120V 60 HZ .03A
FILTER MODEL # ASZEP10-PL
COPYDATE 4/13/2021
For Household Use Only
Children Under 13 Must Be
Supervised By An Adult
Locate the adjustable hanger bracket included
with your filter unit. It could have been placed
inside the filter cartridge compartment.
Place the hanger bracket at 90° and align one
of the adjustment holes onto the mounting post
as shown in the illustration ABOVE.
Then rotate the hook until the hanger is vertical
as shown in the illustration BELOW.
HANGER INSTALLATION
MAINTAINING PROPER WATER LEVEL
TECHNICAL DATA
FILTER
WATTAGE
FLOW RATE
(GPH)
REPLACEABLE
CARTRIDGE
ASZEP10-PL 3.6 45 S
AQUARIUM INTERNAL
POWER FILTER
HANGER BRACKET
HANGER POST
PLACE WIRE THROUGH
CLEAT ON HANGER
Important: Before using the filter submerse the
filter entirely under water until all bubbles disap-
pear. Then hang the filter on the side of the
tank. Always keep in mind maintaining proper
Water Level on the filter is very important to keep
filter running quiet and efficiently. Permitting the
water level to drop below minimum can cause
damage to the filter.
RECOMMENDED WATER LEVEL
MAXIMUM WATER LEVEL
MINIMUM WATER LEVEL
ALWAYS MAINTAIN WATER LEVEL AT
RECOMMENDED WATER LEVEL ON
FILTER TO ASSURE FILTER
FUNCTIONS PROPERLY
DO NOT OPERATE FILTER BELOW MINIMUM LEVEL
Question and Answer IconNeed help?

Do you have a question about the koller ASZEP10-PL and is the answer not in the manual?

Summary

Unit Instructions and Safeguards

Hanger Installation

Maintaining Proper Water Level

Do Not Operate Below Minimum Level

Crucial instruction to prevent filter damage from low water levels.

Maintain Recommended Water Level

Ensures proper filter function and quiet operation.

Technical Data

Maintaining the Filter and Other Important Answers

Filter Cartridge Replacement

Guidance on replacing the filter cartridge every three to four weeks.

Cleaning and Maintenance Precautions

Instructions for cleaning, unplugging, and avoiding detergents.

Important Safety Instructions

Electrical Safety

Warning about damaged cords and exposed wires; discard if damaged.

Aquarium Placement Safety

Advice on preventing water damage and electrical shorts.

Appliance Use by Persons

Safety guidelines for children and individuals with reduced capabilities.

Water Dripping Prevention

Recommendations for preventing wet plugs/receptacles and using GFCI outlets.

One Year Limited Warranty

Warranty Service Contact

Information on how to contact customer service for warranty claims.

Warranty Limitations

Details on excluded warranties and consequential damages.

Overview

This document describes an aquarium internal power filter, detailing its function, installation, maintenance, and safety instructions.

Function Description

The aquarium internal power filter is designed to maintain clean and healthy water conditions in an aquarium. It operates by drawing water through a replaceable filter cartridge, which removes impurities and debris. The filtered water is then returned to the tank, ensuring continuous circulation and purification. The filter is equipped with a UL-approved pump motor, ensuring safe and reliable operation. Proper water level maintenance is crucial for the filter's quiet and efficient functioning, as operating below the minimum water level can cause damage. The filter is intended for household use and requires adult supervision for children under 13.

Usage Features

The filter comes with an adjustable hanger bracket for easy installation on the side of the tank. To install, the hanger bracket is placed at a 90-degree angle and aligned with one of the adjustment holes on the mounting post. It is then rotated until the hook is vertical. A "drip loop" should be created with the power cord to prevent water from dripping onto the electrical outlet, and using a GFCI outlet is recommended for added safety. Before initial use, the filter must be fully submerged in water until all air bubbles disappear. This ensures proper priming and prevents damage. Maintaining the water level between the recommended and maximum marks is essential for optimal performance and to prevent damage. The filter should never be operated below the minimum water level. When medicating fish, the filter cartridge should be removed as it can absorb medications.

Maintenance Features

Regular maintenance is key to the filter's longevity and effectiveness. The filter cartridge should be replaced every three to four weeks, or more frequently if it becomes heavily soiled or if the water flow diminishes. To change the cartridge, the internal filter must first be unplugged from the electrical outlet to stop water flow. The soiled cartridge is then removed, and a new cartridge is rinsed under running tap water before being placed into the filter. After replacing the cartridge, the filter can be plugged back into the electrical outlet. When cleaning the power filter, it is imperative to always unplug it from the electrical power source. Detergents or soap should not be used for cleaning, as their residues can be harmful to fish. The document also provides a QR code and a YouTube link to a video demonstrating how to clean the power filter, offering a visual guide for users. The filter uses specific replacement cartridges, Koller Products Filter Cartridges S (AQ10FC-30), which are widely available from online retailers.

Safety Instructions

Several important safety instructions are provided to ensure safe operation and prevent injury or damage. The unit should not be operated if the power cord or plug is damaged, as the power cord cannot be replaced. Users should inspect the power cord insulation for any cuts or exposed wires; if found, the unit should be discarded, and a new replacement motor ordered. Aquariums should never be placed on surfaces that can be damaged by water, as water can cause electrical shorts or damage fine surfaces. The appliance is not intended for use by individuals with reduced physical, sensory, or mental capabilities, including children under 13, without proper instruction and supervision from a responsible adult. Children under 13 must be supervised to ensure they do not play with the appliance. To prevent the unit's plug or receptacle from getting wet, the tank and stand should be positioned to one side of a wall-mounted receptacle, creating a "drip loop" with the power cord. The use of a GFCI outlet is also recommended for enhanced safety. The filter should never be operated unless fully submerged to the recommended water level, as this can cause damage to the filter.

koller ASZEP10-PL Specifications

General IconGeneral
ModelASZEP10-PL
CategoryWater Filtration Systems
Operating Pressure40-80 PSI
Operating Temperature40-100°F
TypeUnder Sink Reverse Osmosis System
Filtration TechnologyReverse Osmosis
Included ComponentsRO System, Storage Tank, Faucet, Installation Kit, Filters
Stages of Filtration5 Stages