2.
Set the parking brake lever to LOCK position (L).
3.
Raise the work equipment (blade) to the upper limit.
NOTICE
Perform
the following procedure (for lowering the blade to the ground) within 15 seconds after stopping
the engine.
When the engine is stopped, the pressure inside the accumulator gradually goes down, so this inspec-
tion can be performed only immediately after the engine is stopped.
4.
With the work equipment at the upper limit, turn the start-
ing switch to OFF position (A), and stop the engine.
5.
Turn the starting switch to ON position (B).
MAINTENANCE PROCEDURE MAINTENANCE
4-66