Code Fault Possible cause Suggested solution Resetting
53 CAN
Communication
Fault
CAN Communication is not
working
Switch off supply voltage
from all devices that are
connected to CAN bus
Check CAN-bus wiring and
termination resistor settings
Check CAN-communication
parameters
C
55 Board Fault API3 is not installed or not
working properly
Switch off supply voltage
Check API3 supply voltage
Check API3 wiring
connections
If problem recurs, replace
inverter
B
56 Generator Current
Limit/Deceleration
Ramp Supervision
Inverter cannot stop with the
set ramp stretching
Increase P1.8 Deceleration
Time or P11.1 Ramp
Stretching value
C
57 Motor
Overtemperature
Motor temperature too high
Digital input DIA4
deactivated when used for
motor overtemperature
protection
Wait for motor cooling down
Avoid running long periods at
low speed
Check motor temperature
protection wiring
C
58 Overvoltage
Regulator Timeout
Overvoltage regulator has
been active for 5 sec
C
59 Overvoltage at Start Too high supply voltage Measure supply voltage and
check hoist supply voltage
from hoist type plate
C
60 Power unit fault Power unit has stopped
running
E-stop during running
Switch off supply voltage
Check power unit wiring
If problem recurs, replace
inverter
B
61 Overspeed Overspeed situation detected
Interference in speed signal
connected to ENC1A
Check supply voltage
Check load measurement
operation and calibration
Check sensor cable
grounding and inverter PE-
connections
Check/replace speed sensor
connected to ENC1A
A
020145en / Revision D / 2015-04-29
28/31
This document and the information contained herein, is the exclusive property of Konecranes Plc. and represents a non-public, confidential and proprietary trade secret that may not be
reproduced, disclosed to other parties, altered or otherwise employed in any manner whatsoever without the express written consent of Konecranes Plc.
Copyright
©