Code Alarm Possible cause Suggested solution
87 Programmable limit
active
Programmable limit is
disabling driving in
either direction
Run other direction
Set the
programmable limit to
other position
Limit can be also by-
passed temporarily
by activating the
movement control
more than 5 seconds
88 CCU fault Controlled common
use fault.
Another device that is
connected in CAN bus
has an active fault.
93 CCU activation Controlled common
use activation.
Another device that is
connected in CAN bus
has caused the
stopping.