12
o Max. motor current - TelMe-Parameter
threshold for motor current peaks in A. Here the
warning on the transmitter is activated.
o Max. BEC current - TelMe-Parameter threshold
for BEC current in mA. Here the warning on the
transmitter is activated. (Only with ESCs having
BEC current measuring. Not for all transmitters)
Limits: Min 0mA - Max 30000mA
o Max. FET temperature - TelMe-Parameter
threshold for temperature of power MosFets in
°C, Here the warning on the transmitter is
activated.
Limits: Min 20°C - Max 90°C
Default: 90°C
o Max. BEC temperature - TelMe-Parameter
threshold for BEC temperature in °C Here the
warning on the transmitter is activated. (Only at
ESCs with BEC)
Limits: Min 20°C - Max 90°C
Default: 90°C
o Telemetry front - activates internal TelMe
module on the front sensor port (only for
KOLIBRI ESC)
If you select your protocol the Telemetry can be
used on your Transmitter.
o Telemetry side - activates internal TelMe
module on the side sensor port (only for KOLIBRI
140 LV)
Please note that the FUTABA protocol can
only be chosen on the front port.
Expert
The following parameters shall only be changed by
experts. Wrong values can generate malfunctions or
damage the ESC.
o Min. PWM - minimum adjustable PWM-Value.
Affects the Spool Up.
Limits: Min 1% - Max 25%
o Max. starting current - Limits the max. A
during the Startup. Affects the Spool Up.
Limits: Min 10A - Max 100A
o Slewrate Pos.
Affects how fast a higher RPM is reached. The
time refers to 0-100% PWM.
Limits: Min 100ms - Max 60.000ms
Default: 1000ms
o Slewrate Neg.
Affects how fast a lower RPM is reached. The
time refers to 100-0% PWM.
Limits: Min 100ms - Max 60000ms
Default: 1
o Brake-Slewrate Pos. - Affects how fast a
higher brake value is reached. The time refers
to 0-100% braking effect.
Limits: Min 100ms - Max 10000ms
o Brake-Slewrate Neg. - Affects how fast the
ESC brakes the Motor down. The time refers
to 100-0% braking effect.
Limits: Min 100ms - Max 10000ms
o Min. PWM Brake. - With this value you can
set how slow the brake can be, compared to
max. effect of the brake.
Attention: only with proportional brake.
Limits: Min 0% - Max 50%
Default: 0%
o Max. PWM Brake - with this value you can set
how strong the brake should slow the motor
down.
Attention: only with proportional brake.
Limits: Min 50% - Max 100%
Default: 100%
Firmware-Info
The software status is displayed when the ESC is
connected.