Instructions for
installation and service
for control unit
FR4.1
12 - 24 Volt DC
ID#: 11002347AA
Version: A00
Vailed from 08/2014
Question and Answer IconNeed help?

Do you have a question about the KONVEKTA FR4.1 and is the answer not in the manual?

Summary

Technical data of control unit

General description of the control unit

Connecting and Safety instructions

Provides safety guidelines, installation, mounting, electrical, and sensor connection procedures.

Functions of buttons

Details the functions of the four control buttons and setpoint adjustment.

Faults - indications and signals

Adjustment of Parameters in the menu

Example for change of a parameter, here parameter defrost interval “d.dı”

Demonstrates the process of modifying a specific parameter, including password entry and navigation.

Conversion to cooling with recirculated air defrosting; or replace a FR1, FR2, FR3 or FR4

Details parameter adjustments needed for converting to recirculated air defrosting or replacing older models.

Conversion to cooling - heating with hotgas - defrosting with hotgas

Explains parameter changes for enabling heating and hot gas defrosting modes.

Control of defrosting

Configuration of the parameters with “FR 4 copy-key”

Logic >> Explanations for the functions of the control conditions

Summary

Technical data of control unit

General description of the control unit

Connecting and Safety instructions

Provides safety guidelines, installation, mounting, electrical, and sensor connection procedures.

Functions of buttons

Details the functions of the four control buttons and setpoint adjustment.

Faults - indications and signals

Adjustment of Parameters in the menu

Example for change of a parameter, here parameter defrost interval “d.dı”

Demonstrates the process of modifying a specific parameter, including password entry and navigation.

Conversion to cooling with recirculated air defrosting; or replace a FR1, FR2, FR3 or FR4

Details parameter adjustments needed for converting to recirculated air defrosting or replacing older models.

Conversion to cooling - heating with hotgas - defrosting with hotgas

Explains parameter changes for enabling heating and hot gas defrosting modes.

Control of defrosting

Configuration of the parameters with “FR 4 copy-key”

Logic >> Explanations for the functions of the control conditions

KONVEKTA FR4.1 Specifications

General IconGeneral
Storage Temperature-40°C to +85°C
Relative Humidity5% to 95% (non-condensing)
Number of Digital Outputs4
Number of Analog Inputs2
Number of Analog Outputs2
Operating Voltage24 V DC
Communication InterfaceCAN

Related product manuals