36
Phenomenon Cause
Intermittent stop during operation Defrosting is in operation
Low dehumidication capacity The dehumidication capacity de-
creases as the temperature and
humidity in the room change.
Room humidity does not decrease The area of the room is too large,
which is beyond the scope of the
appliance. The door and windows
of the room are not closed.
Unpleasent odour The smell may come from walls,
furniture and other things
The unit emits a sound during ope-
ration
The noise produced by the coolant
ow can be eliminated or lowered
automatically while the system is
operating stably.
Tank ll indicator light is on When the water tank is full, the
FULL indicator light is lit to remind
you to empty it.
TECHNICAL SPECIFICATIONS
Dehumidification capacity
- 10 L / day (30°C, 80%)
- 5 L / day (27°C, 60%)
Power supply: AC220V-240V, 50Hz
Power: 200 W (27°C, 60%), 245 W (32°C, 90%) Current: 1.25 A (27°C,
60%), 1.4 A (32°C, 90%) Water tank capacity: 2. 5L
Airflow: 120 m3/h
Sound pressure level: 42 dB(A) Refrigerant: R290
Refrigerant charge R290: 30 g Inlet pressure: 1.2 MPa
Outlet pressure: 2.5 MPa Weight: 9.5 Kg
Minimum surface area: 4 m2 Maximum surface area: 50 m2
The equipment must be installed, commissioned and stored in a room with
a surface area Greater than 4 m2