These hobs must be connected to the mains using a socket in
compliance with publication IEC 60083 or an all-pole circuit-
breaker device in compliance with the installation rules in force.
Your appliance should be positioned so that the mains switch is
accessible. When power is rst supplied to your hob, or after an
extended power cut, an indicator light will appear on the control
panel. Wait for 30 seconds approximately until this information
disappears before using your hob (This display is normal and it is
intended, if applicable, for your after-sales service. In all cases,
the user of the hob should disregard it).
If the cable is damaged it must be replaced by the
manufacturer, its aftersales service or a person with a
similar quali cation to prevent danger.
Hook-up of 220-240V ~ - 32A
Hook-up of 400V 2N ~ - 16A
Separate the 2 phase wires (L1 and L2) before
connection.
For a 400 V 2N triphase connection, if your
hob malfunctions, check that the neutral
conductor is properly connected.
Hook-up of 2x230V 2L+2N ~ - 16A
Separate the wires before connection.
Electrical connection