Electrical connection
The machine is supplied with an electrical power cord with plug.
The mains plug must be fitted to a standard grounded socket
with a 30mA residual current operated device. The socket must
be protected with a 16A delay action fuse on the mains side.
KRÄNZLE 1150 / 1150 T - 220-240 VKRÄNZLE 1150 / 1150 T - 220-240 V
KRÄNZLE 1150 / 1150 T - 220-240 VKRÄNZLE 1150 / 1150 T - 220-240 V
KRÄNZLE 1150 / 1150 T - 220-240 V
olt 50 Hzolt 50 Hz
olt 50 Hzolt 50 Hz
olt 50 Hz
KRÄNZLE 1120 / 1120 T - 110-117 VKRÄNZLE 1120 / 1120 T - 110-117 V
KRÄNZLE 1120 / 1120 T - 110-117 VKRÄNZLE 1120 / 1120 T - 110-117 V
KRÄNZLE 1120 / 1120 T - 110-117 V
olt 60 Hzolt 60 Hz
olt 60 Hzolt 60 Hz
olt 60 Hz
KRÄNZLE 1150 / 1150T - 220-240 VKRÄNZLE 1150 / 1150T - 220-240 V
KRÄNZLE 1150 / 1150T - 220-240 VKRÄNZLE 1150 / 1150T - 220-240 V
KRÄNZLE 1150 / 1150T - 220-240 V
olt 60 Hzolt 60 Hz
olt 60 Hzolt 60 Hz
olt 60 Hz
When using an extension cable, this must have an earthed lead
which is properly connected to the socket. The conductors in the
extension cable must have a minimum cross section of 1.5 mm².
Plug connections must be of a spray-proof design, and may not
be located on a wet floor.
(with extension cables of more than 10 m - 2.5 mm
2
)
CAUTION !
The use of extension cables which are too long may lead to malfunctions
and start up difficulty.
When using a cable drum, always keep the cable wound as far as possible.