12/10/2020 PK
SERVICE, INSTALLATION AND INSTRUCTION MANUAL
68K-759HC, 68K-773HC
69K-887HC, 69K-888HC
REACH-IN REFRIGERATOR
PLEASE READ CAREFULLY

Questions and Answers

  • E
    Ellen NobleAug 10, 2025
    Why is the compressor not running on my KRATOS 69K-887HC?
    • M
      Max LewisAug 10, 2025
      If the compressor of your KRATOS Refrigerator isn't running, there are several potential causes: * A fuse may be blown, or the circuit breaker may have tripped. In this case, replace the fuse or reset the circuit breaker. If this doesn’t fix the problem, contact a qualified service technician. * The power cord might be unplugged. Ensure the power cord is plugged in and check that the relevant breaker isn’t tripped. * The thermostat may be set too high. Try setting the thermostat to a lower temperature. * A ground fault protector may have tripped. Reset or eliminate the GFI breaker or receptacle.
  • J
    jwebbAug 17, 2025
    What to do if the KRATOS 69K-887HC cabinet temperature is too warm?
    • J
      Joshua MccoyAug 17, 2025
      If the cabinet temperature of your KRATOS Refrigerator is too warm, consider the following: * The thermostat may be set too high. Adjust the thermostat to a lower temperature. * Airflow might be blocked. Re-arrange the products inside to allow for proper air flow, ensuring at least four inches of clearance from the fan. * Low refrigerant levels could be the issue. Contact a qualified service technician to check refrigerant levels. * The door may be slightly ajar. Ensure the door is completely closed.
  • S
    Sheena ColeAug 25, 2025
    Why is my KRATOS 69K-887HC Refrigerator making a loud noise?
    • A
      alexmannAug 25, 2025
      If your KRATOS Refrigerator is making a loud noise, here are a few possible reasons: 1. The floor may be too weak, or the unit isn't level. Check the installation to confirm the unit is level and adjust the tray position. 2. The back of the unit could be too close to the wall. 3. The tray might not be in the correct position. 4. The fan blade may be obstructed or unbalanced. Clear any obstruction from the fan blade or replace the fan.
  • D
    David SmithSep 2, 2025
    How to fix an iced over evaporator in KRATOS 69K-887HC?
    • S
      stephaniebrownSep 2, 2025
      If the evaporator in your KRATOS Refrigerator is iced over, it might be due to excessive moisture or an incorrectly set auto defrost cycle. You can run the manual defrost cycle or unplug the unit and open the door.

Summary

Appliance Safety Instructions

Important Safety Instructions

Essential safety precautions to reduce risks of fire, electric shock, or injury.

Important Safeguards

Danger Warnings

Critical warnings about electrical safety, proper circuit use, and avoiding hazards.

General Warning Precautions

Precautions for installation, handling cold surfaces, ventilation, and general usage.

Electrical Connection and Power Surges

Appliance Installation Guidelines

Operation Overview and Thermostat Controls

Front Panel Commands

Explanation of the buttons and their functions on the thermostat control panel.

Main Functions and Alarm Management

Operation and Maintenance Tips

Cleaning and Maintenance Procedures

Safety Warnings and Maintenance Benefits

Critical safety warning for service and benefits of ongoing maintenance.

Troubleshooting Guide

Troubleshooting Chart

A table listing faults, probable causes, and recommended actions for common problems.

Service and Troubleshooting Tips

Wiring Diagrams

Single Door Models Wiring Diagram

Wiring diagram specific to the single door refrigerator models.

Double Door Models Wiring Diagram

Wiring diagram specific to the double door refrigerator models.

KRATOS 69K-887HC Specifications

General IconGeneral
BrandKRATOS
Model69K-887HC
CategoryRefrigerator
LanguageEnglish

Related product manuals