EasyManua.ls Logo

Krohn-Hite 3320 Series - User Manual

Default Icon
31 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
DIGITALLY TUNED
VARIABLE FILTER
3320 SERIES
MODEL NO._ SERIAL NO.
OPERATING AND MAINTENANCE
MANUAL
KROHN-H1TE CORPORATION
AVON INDUSTRIAL PARK/SODWELL STREET/AVON, MASS. 02322
1978 KROHN-HITE CORPORATION
Question and Answer IconNeed help?

Do you have a question about the Krohn-Hite 3320 Series and is the answer not in the manual?

Summary

General Description

Introduction to Filter Operation

Provides operation and maintenance instructions, specifications, schematic diagram and parts list for Models 3320, 3321, 3322 and 3323 filters.

Filter Specifications Overview

Details frequency range, bands, multipliers, frequency control, calibration accuracy, and bandwidth for the filters.

Filter Response Characteristics

Explains flexibility of bandwidth adjustment, showing low-pass, high-pass, band-pass and band-reject responses.

Operating Instructions

Introduction to Operating Instructions

Instructions for unpacking, examining for damage, and general setup of the filter unit, including rack-mounting.

Front and Rear Panel Controls

Description of front and rear panel controls, including frequency, function, gain, and power switches.

General Filter Operation

Details the step-by-step procedure for operating Model 3320 and 3321 filters.

Model 3322 and 3323 Operation

Provides instructions for obtaining High-Pass or Low-Pass operation with 48 db per octave attenuation for dual-channel models.

Band-Pass Operation (24 dB;Octave)

Details cascading channels for band-pass operation with 24 db per octave attenuation, including bandwidth considerations.

Band-Reject and Notch Filter Operation

Provides steps for parallel connection of channels to achieve band-reject or notch filter operation.

Hum and Noise Considerations

Discusses the composition of hum and noise and how filter settings affect it.

Input and Output Terminals

Describes the BNC coaxial connectors provided on the front and rear panels for input and output.

Power Requirements

Details line operation power requirements and modifications for different line voltages.

Optional Battery Kit

Information on ordering and installing an optional battery kit for uninterruptible power.

Battery Installation Procedure

Step-by-step guide for installing batteries, including types and connection details.

Circuit Description

Introduction to Circuitry

Overview of the four-pole, variable electronic filter and its operating modes (Low-Pass, High-Pass).

Detailed Circuit Breakdown

Provides a detailed breakdown of the filter's circuit components and their functions.

Input Amplifier Circuit

Details the two-stage operational amplifier circuit for signal input, including FETs and transistors.

Network Amplifier Circuit

Explains the operation of Network Amplifiers, typically consisting of transistors and associated components.

R-C Tuning Network Details

Describes the R-C tuning elements and amplifier stages forming the filter's frequency characteristic.

Output Amplifier Circuit

Details the four-stage operational amplifier circuit responsible for the filter's output signal.

Butterworth vs. RC Response

Explains the Butterworth and RC response characteristics and how the FUNCTION switch selects them.

Power Supply Circuits

Describes the unregulated and regulated power supplies used in the 3320 Series filters.

Maintenance Procedures

Introduction to Maintenance

Procedure for locating the source of trouble, accessing components, and general troubleshooting guidance.

Power Supply Maintenance

Guidance on checking the two power supplies for correct operation and voltage levels.

Signal Tracing for Troubleshooting

Procedure for localizing malfunctions by tracing the signal path through the filter circuit.

Low-Pass and High-Pass Malfunction

Specific troubleshooting steps for malfunctions in Low-Pass and High-Pass modes, including test points.

Input Amplifier Troubleshooting

Troubleshooting the Input Amplifier by monitoring DC levels and tracing error signals.

Output Amplifier Troubleshooting

Troubleshooting the Output Amplifier by checking DC levels and tracing error signals.

Tuning Circuit Troubleshooting

Procedure to identify faulty resistive or capacitive elements within the tuning circuits.

Network Amplifier Troubleshooting

Troubleshooting the Network Amplifiers by checking DC levels and tracing feedback signals.

Calibration Error Troubleshooting

Methods for identifying calibration errors by measuring test points with an AC meter and oscilloscope.

Calibration and Adjustment

Introduction to Calibration

Procedure for incoming acceptance and periodic maintenance checks, adhering to original specifications.

Detailed Calibration Specifications

Covers cutoff frequency calibration, pass-band gain, attenuation slope, maximum attenuation, output impedance, and hum/noise.

Required Test Equipment

Lists the necessary test equipment for performing calibration and maintenance procedures.

General Calibration Procedure

Outlines general procedures for DC voltage measurements, visual inspection, and locating adjustments.

Power Supply Calibration Checks

Details how to check the plus and minus 9 volt supplies with respect to ground during operation.

Detailed Test Procedure

Provides a step-by-step test procedure to check filter performance, including setup and limits.

Krohn-Hite 3320 Series Specifications

General IconGeneral
BrandKrohn-Hite
Model3320 Series
CategoryWater Filtration Systems
LanguageEnglish