SPECIAL CONDITIONS 2
19
OPTIMASS / 400
www.krohne.com10/2022 - 4003491806- AD OPTIMASS 400 Atex R06 en
OPTIMASS 6400C with Stainless Steel converter housing
VE ab c...i j k...m n p q r...w
71...79 0 0 0 or 1
Ambient temp. T
amb
°C Max. process temp. T
m
°C
Temp. class Max. surface temp. °C
-40...+30 150 T3 - T1 T190
-40...+35 145 T3 - T1 T185
-40...+40 40 T6 - T1 T80
125 T3 - T1 T165
-40...+45 110 T3 - T1 T150
-40...+50 90 T4 - T1 T130
-40...+55 55 T5 - T1 T95
75 T4 - T1 T115
-40...+60 60 T4 - T1 T100
Minimum process temperature: T
amb
-35°C T
m
= -50°C, T
amb
<-35°C T
m
= -40°C
Table 2-3: