10.
Maintenance
The heater requires little maintenance activity. Following the manufacturer’s recommendations will ensure safe
and failure-free operation of the device:
clean the furnace bowl and other combustion chamber elements everyday before firing up. The maximal device
operation time without cleaning the bowl is about 7-12 hours (depending on the employed oil intended for
combustion)
check the passability of the overflow pipe (the pipe in the lower part of the combustion chamber, directly over
the overflow bowl), clean if necessary.
clean the combustion chamber base (the element under the furnace bowl) at least once a week
check whether the air inlet openings in the lower and upper part of the combustion chamber are not blocked
clean the rubber duct feeding oil onto the furnace bowl at least once a week
clean the fuel tank and oil pump filter during the heating season
if the heater is going to be off for a longer time, carefully clean the combustion chamber and the furnace bowl
and protect them against corrosion by coating them with a thin layer of oil
CAUTION!!!
DUE TO EXHAUST DUST ACCUMULATING
IN THE PIPE EXCHANGER, IT IS ADVISABLE TO CLEAN IT AT LEAST ONCE A
YEAR BEFORE THE HEATING SEASON!