2.9 Malfunction and remedy
All work on the refrigeration system is to be
done by specialised persons only
Attention
Malfunction Possible Cause Remedy
The appliance is plugged in but
compressor and evaporator fail
to function
a) No current
b) Hygrostat incorrectly set
c) Technical fault in refrigeration
system
a) Check fuses and electrical
connections
b) Check hygrostat setting
c) Contact after-sales service
Appliance runs but no conden-
sation forms on evaporator
a) Operating temperature range
not reached or exceeded
b) Operating air humidity range
not reached
c) Suction wall or blow-out wall
obstructed
d) Technical fault in refrigeration
system
a) Use appliance in correct
temperature range conditions or
adjust room temperature accor-
dingly
b) Use appliance only at 30 %
humidity or above
c) Allow adequate clearance of
the appliance, clean or change
theairlter.
d) Contact after-sales service