EasyManua.ls Logo

Kronoterm KT-2A - 6.7 HEATING THE POOL; Pool Heating Loop Modes; Pool Temperature Setting; Pool ECO Mode Settings

Kronoterm KT-2A
36 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
24
6.7. HEATING THE POOL
Pool
Menu
Parameter name Parameter value range Note
Pool
heating loop
operational
mode
ON Turn on
AUTO – Working schedule
OFF Turn off
Setting the
pool loop
temperature
+15 °C to 40 °C Set the desired pool water temperature.
ECO pool mode –10 °C/+10 °C ECO lowering the pool temperature by the set value.
COMFORT pool
mode
–10 °C /+10 °C
COMFORT raising the pool temperature by the set
value.
Setting the
schedule
1–7 days
0–24 h
Weekly operational schedule.
N
If there is no KT-1/KT-2A thermostat, adaptive regulation is turned off. The KSM regulator calculates the
temperature of the water in the heating loop based on the heating curve with reference temperatures at −15 °C
and +15 °C.
For a constant water temperature in the heating system set the setting at -15°C and at +15°C to the same value.
Operating instructions
A System
17-19-45-6702-02