EasyManua.ls Logo

Kronoterm KT-2A - 6.11 SYSTEM SETTINGS; Temperature Offset Adjustment; Heating Loop Operational Mode Settings; Operational Mode Switching

Kronoterm KT-2A
36 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
27
6.11. SETTINGS
Setting
Menu
Parameter name Parameter value range Note
Temperature
offset
-4 °C/+4 °C
Heating loop
operational
mode
ECO
AUTO
COMFORT
General heating loop operating mode.
Switching
operational
modes
ON – automatic switch
OFF – deactivate automa-
tic switch
ON - automatic switch between heating and cooling.
If you deactivate automatic switching, you must
ensure to manually switch modes.
Screed-drying
ON – Turn on
OFF – Turn off
Program sušenja estriha.
Heating system
pressure
1 – 1.3 bar The heating system pressure can be max. 2.5 bar.
Adaptive curve
loop 1
ON – Turn on
OFF – Turn off
Adaptive regulation automatically turns off if it is set
that way at commissioning.
Adaptive curve
loop 2
ON – Turn on
OFF – Turn off
Adaptive regulation automatically turns off if it is set
that way at commissioning.
Adaptive curve
loop 3
ON – Turn on
OFF – Turn off
Adaptive regulation automatically turns off if it is set
that way at commissioning.
Adaptive curve
loop 4
ON – Turn on
OFF – Turn off
Adaptive regulation automatically turns off if it is set
that way at commissioning.
Operating instructions
A System
17-19-45-6702-02