27
6.11. SETTINGS
Setting
Menu
Parameter name Parameter value range Note
Temperature
offset
-4 °C/+4 °C
Heating loop
operational
mode
ECO
AUTO
COMFORT
General heating loop operating mode.
Switching
operational
modes
ON – automatic switch
OFF – deactivate automa-
tic switch
ON - automatic switch between heating and cooling.
If you deactivate automatic switching, you must
ensure to manually switch modes.
Screed-drying
ON – Turn on
OFF – Turn off
Program sušenja estriha.
Heating system
pressure
1 – 1.3 bar The heating system pressure can be max. 2.5 bar.
Adaptive curve
loop 1
ON – Turn on
OFF – Turn off
Adaptive regulation automatically turns off if it is set
that way at commissioning.
Adaptive curve
loop 2
ON – Turn on
OFF – Turn off
Adaptive regulation automatically turns off if it is set
that way at commissioning.
Adaptive curve
loop 3
ON – Turn on
OFF – Turn off
Adaptive regulation automatically turns off if it is set
that way at commissioning.
Adaptive curve
loop 4
ON – Turn on
OFF – Turn off
Adaptive regulation automatically turns off if it is set
that way at commissioning.
Operating instructions
A System
17-19-45-6702-02