  • H
    hartkathrynAug 4, 2025
    What to do if my Krystal Pure KS15HE Water Dispenser is not providing soft water after regeneration?
    • H
      Haley Scott MDAug 4, 2025
      If your Krystal Pure Water Dispenser isn't providing soft water after regeneration, there might be a few reasons. First, check the power source to ensure the unit is regenerating. Second, make sure there is enough salt in the brine tank; if not, add salt. Lastly, the injector might be clogged, so clean the injector and drain with water.
  • D
    Donald JordanAug 8, 2025
    Why is my Krystal Pure KS15HE using more or less salt than the control setting?
    • S
      Shawn MartinAug 8, 2025
      If your Krystal Pure Water Dispenser uses the wrong amount of salt, it could be due to incorrect settings; ensure you have the correct adjustments. Foreign material might also be causing incorrect flow rates in the control. Remove the variable salt control and flush out any foreign matter. Manually position the control to 'brine draw' to clean it, then to 'purge' to remove brine from the tank. If these steps don't resolve the issue, the control itself may be defective and need replacement.
  • E
    Ethan GreenAug 13, 2025
    What to do if my Krystal Pure KS15HE Water Dispenser control does not draw brine?
    • J
      Jenna Harris MDAug 13, 2025
      If the control of your Krystal Pure Water Dispenser isn't drawing brine, it could be due to several reasons. First, low water pressure may be the cause; adjust the pump to maintain the conditioner at 30 PSI. There might be a restriction in the drain line, so remove any obstructions. Also, the injector could be clogged, so clean the injector and the presentation window. If the injector is defective, replace it. Lastly, valve 2 or 4 might not be closed; remove any foreign materials from the disc and check if the disc closes by pushing on the stem. Replace if necessary.
  • M
    Melissa OrtegaAug 17, 2025
    What to do if there is overflowing in the brine tank of my Krystal Pure KS15HE?
    • I
      icrawfordAug 17, 2025
      If your Krystal Pure Water Dispenser's brine tank is overflowing, it might be because the brine valve (1) is open; manually operate the valve stem to remove any obstruction. The brine flow rate may also be uncontrolled; remove the variable salt control to clean it. Another cause could be that valve 3 or 4 isn't closed when brine is being drawn, causing refill; remove any foreign material keeping the disc open and manually operate the valve stem. Finally, check all brine line connections for air leaks.
  • P
    Patricia JosephAug 21, 2025
    Why is the backwash frequency of my Krystal Pure Water Dispenser control too high or too low?
    • A
      Anthony HessAug 21, 2025
      If the backwash frequency of your Krystal Pure Water Dispenser control is too high or too low, the backwash control might be incorrect; replace it with the correct size control. Also, foreign material might be affecting the control's operation; remove the controller and ball, then drain with water.
  • K
    Kyle MyersAug 26, 2025
    What to do if there's intermittent or irregular brine draw in my Krystal Pure KS15HE Water Dispenser?
    • A
      Antonio RoseAug 26, 2025
      If your Krystal Pure Water Dispenser is experiencing intermittent or irregular brine draw, low water pressure could be the cause; adjust the pump to maintain the softener/conditioner at 30 PSI. Additionally, a defective injector may be the problem; replace the injector and the injector cap.
  • J
    Jade ElliottAug 30, 2025
    Why is there constant water flow and dripping in the drain or brine line of my Krystal Pure KS15HE after regeneration?
    • P
      Patricia StewartAug 30, 2025
      If you notice continuous water flow and dripping in the drain or brine line of your Krystal Pure Water Dispenser after regeneration, the drain valve (5 or 6) or the brine valve (1) might be open due to foreign material or particles; manually operate the valve stem to remove the obstruction. Alternatively, the return spring on the valve stem in the top plate could be weak; replace the spring.

Summary

Owners Manual

Introduction to Water Softening

Important Warnings

Critical safety precautions for installation, operation, and maintenance to prevent damage or injury.

Specifications and Limitations

Installation Inspection and Preparation

Installation Procedures Overview

Connecting to Water Supply

Connecting to Drain Line

Connecting the Brine Line

System Start-Up Procedures

Connecting Electrical Power

Programming the Valve Control

Use and Care Guide

Troubleshooting Common Issues

Valve Troubleshooting

Diagnosing and resolving issues related to the control valve's operation.

KS5 & KS10 Control Troubleshooting

Specific troubleshooting for KS5 and KS10 control unit problems like clock display.

General Control System Troubleshooting

Resolving common control system problems like flow display or regeneration timing.

Manufacturers Limited Warranty

Krystal Pure KS15HE Specifications

General IconGeneral
Cold Water Temperature5-10°C
Voltage220-240V
Weight12 kg
TypeWater Dispenser
MaterialPlastic
CertificationCE