Do you have a question about the KStar BluE-H5 and is the answer not in the manual?
Explains Self Consume, Peak Shift, and Battery Priority modes.
Manual keeping, operator requirements, and warning signs.
Hazard information and classification of Lithium Iron Phosphate Battery.
Dangers and warnings related to high voltage and chemical risks.
General and restricted site requirements for installing the H5/H3 system.
Step-by-step guide for battery installation.
Step-by-step guide for inverter installation.
Step-by-step guide to safely power on the system.
Step-by-step guide to safely power off the system.
Actions to take for abnormal system operation or emergencies.
Specific steps for handling system faults and contacting support.
Firefighting instructions and appropriate extinguishing media.
Details on PV input, bus voltage, battery, and other parameter displays.
Shows alarm and error codes for system faults.
Allows configuration of system status, grid standards, and PV input.
Main interface for system settings and inquiries.
Access to system information and configuration options.
Selectable operational modes: Self Consume, Peak Shift, Battery Priority.
Interface for selecting and configuring battery parameters.
Selects the type of battery (LEAD-ACID, LFP, etc.).
Sets the battery charging current limit.
Sets the battery discharge percentage.
Sets the battery charging percentage.
Sets the battery cut-off voltage.
Selects country-specific grid connection standards.
Configuration for run settings like reactive power and grid parameters.
Sets reactive compensation mode (Power Factor, Reactive Power).
Adjusts the power factor value.
Sets the reactive power percentage.
Configures grid export limit (percentage).
Sets maximum voltage limits for INV and Grid.
Sets maximum frequency limits for INV and Grid.
Sets minimum frequency limits for INV and Grid.
Enables or adjusts over-voltage derating function.
Enables or adjusts under-voltage derating function.
Enables or adjusts over-frequency derating function.
Step-by-step guide for battery recharging.
Lists alarm codes (Wxx) and their English descriptions.
Lists error codes (Fxx) and their English descriptions.
Table listing common faults, codes, and solutions.
Solution for F00 Soft Time Out fault.
Solution for F01 INV Volt Short fault.
Solution for F02 GFCI Sensor Fault.
Solution for F04 Bus Volt Low fault.
Solution for F06 Bus Volt Short fault.
Solution for F07 PV ISO Under Fault.
Solution for F10 INV Current Over fault.
Solution for F11 INV DC Over fault.
Solution for F13 NTC/Sink Temp Over fault.
Solution for F15 Dischg Curr Over fault.
General maintenance checks for connections and equipment.