SPECIFICATIONS
Power supply
Consumption
Consumption in Stop mode
Operating temperature
Sound level of siren (1 m)
Self-supply autonomy
Remote controls
Sensitivity of internal movement sensor
12Vcc (10V-15V)
1,8 mA
0 mA
- 25°C + 85°C
114 dB
5 minutes
72 million billion variable codes (lithium battery)
1,5° per second
CAPACTITY OF CONTROLS
Direction indicator relay
Horn control
5A + 5A
Negative electronic 300mA
TIMING
Initial immunity phase
Duration of alarm cycle
Interval between alarm cycles
Passive arming delay
Stop mode delay
Intermittence of direction indicators
26 seconds
26 seconds
5 seconds
50 seconds
5 days
0,4 sec.off/0,4 sec.on
EN
17
ALARM CYCLES
Contact alarm inputs
Ignition sensing
Cable tampering
10 cycles
10 cycles
9 cycles