G3601-8911-8

Table of Contents

Questions and Answers

  • M
    Molly LynchSep 15, 2025
    What to do if my Kubota KJ-S130VX Portable Generator has valve clearance wrong?
    • R
      Richard KellySep 15, 2025
      If the valve clearance is wrong on your Kubota Portable Generator, adjust the valve clearance to 0.18 to 0.22 mm when the engine is cold for engine models D1703-EBG and V2203-EBGx. For engine model V3300-EBGx, adjust valve clearance to 0.23 to 0.27 mm when the engine is cold.
  • N
    nealaudreyAug 25, 2025
    Why is my Kubota KJ-S130VX frame overheated?
    • G
      garciakarenAug 25, 2025
      The frame of your Kubota Portable Generator might be overheating due to several reasons: the cooling fan inlet or outlet is blocked (unblock the inlet or outlet), the voltage is too high (readjust the voltage), or the generator is overloaded (reduce the load).
  • L
    louisallenAug 25, 2025
    Why is my Kubota Portable Generator making unusual noise or vibration?
    • R
      Robert VillegasAug 26, 2025
      Unusual noise or vibration in your Kubota Portable Generator can be caused by a single-phase load applied beyond the allowable level (lower the load to acceptable level), a deteriorated bearing (replace the bearing), or a damaged coupling (replace the coupling).
  • W
    williamskevinAug 26, 2025
    What to do if the voltage of my Kubota KJ-S130VX is too high?
    • J
      Jennifer BerryAug 26, 2025
      If the voltage of your Kubota Portable Generator is too high, it could be due to maladjusted voltage (readjust using the voltage control), a broken AVR voltage detection cable (repair the cable), a faulty AVR (replace the AVR), or a conductive load connected such as a mercury arc lamp (disconnect such load).
  • M
    mathewsjessicaSep 16, 2025
    What to do if my Kubota KJ-S130VX Portable Generator air cleaner is dirty?
    • D
      Daniel MullinsSep 16, 2025
      If the air cleaner of your Kubota Portable Generator is dirty, clean the element every 250 hours of operation.
  • J
    James DavisSep 23, 2025
    What to do if my Kubota KJ-S130VX fuse blows?
    • T
      tammyspenceSep 23, 2025
      Replace the fuse.
  • W
    Wendy RomanSep 8, 2025
    What to do if my Kubota KJ-S130VX Portable Generator has a bad nozzle?
    • M
      Michelle DodsonSep 8, 2025
      If your Kubota Portable Generator has a bad nozzle, replace it with a new one if necessary.
  • B
    Bobby HardySep 9, 2025
    What to do if moving parts are overheated due to shortage of lubrication oil or improper lubrication in my Kubota KJ-S130VX Portable Generator?
    • D
      David HebertSep 9, 2025
      If moving parts are overheated due to a shortage of lubrication oil or improper lubrication in your Kubota Portable Generator, check the amount of engine oil with the oil level gauge. Also, check the lubricating oil system. At every second oil change, the oil filter cartridge should be replaced. Check to see if the engine bearing clearances are within factory specs.
  • R
    Ryan JensenSep 2, 2025
    What to do if my Kubota Portable Generator has air or water mixed in fuel system?
    • V
      Vanessa MorrisSep 2, 2025
      If air or water is mixed in the fuel system of your Kubota Portable Generator, and air is in the fuel filter or injection lines, the fuel pump will not work properly. To attain proper fuel injection pressure, check carefully for loosened fuel line coupling, cap nut and etc. Loosen joint bolt atop fuel filter and air vent screws of fuel injection pump to eliminate all the air in the fuel system.
  • B
    brian85Aug 31, 2025
    What to do if my Kubota Portable Generator pilot lamp failure to light up?
    • A
      allenmichaelAug 31, 2025
      If the pilot lamp on your Kubota Portable Generator fails to light up, it could be due to a broken lamp bulb (replace the bulb) or the generator voltage being too low (see "Voltage failure to rise" above).

Summary

Servicing of Generator

Specifications

General Type (50 Hz) Specifications

Technical details for 50Hz general type generator models.

General Type (60 Hz) Specifications

Technical details for 60Hz general type generator models.

AUS Type (50 Hz) Specifications

Technical details for Australian 50Hz generator models.

Instrument Panel and Part Names

Control Panel Layout and Indicators

Identifies and explains generator control panel components and indicators.

Generator Component Identification

Labels and identifies the main physical parts of the generator unit.

Preparation for First Operation

Battery Installation and Charging

Guide for preparing the battery before initial generator use.

Engine Oil Filling Procedure

Instructions for adding the correct engine oil and capacity.

Coolant Level Check and Filling

Procedure for checking and filling the engine's coolant system.

Fuel System Preparation and Handling

Details on fuel type, tank capacity, and safe refueling practices.

Fuel Line Air Bleeding

Steps to remove air from the fuel system for proper engine operation.

Electric Power Supply Connection

Guidelines for generator grounding and connecting power safely.

Load Capacity and Device Matching

Information on matching electrical devices to generator capacity.

Pre-Operation Check

Daily Inspection Checklist

Essential checks to perform before each generator operation.

Operating the Engine

Engine Starting Procedure

Step-by-step guide for starting the generator engine safely.

Cold Weather Starting Guide

Procedures for starting the engine in low temperatures.

Engine Overheating Precautions

Actions to take if the engine temperature becomes critically high.

Engine Stopping Procedures

Correct methods for shutting down the generator engine.

Engine Warming Up Procedure

Recommended steps for warming up the engine before use.

Maintenance

Anti-freeze and Fluid Disposal

Safety precautions for handling and disposing of engine fluids.

Service Intervals Schedule

Recommended maintenance tasks based on operating hours or time.

Daily Maintenance Checks

Routine inspections to ensure optimal generator performance.

Initial 50 Hours Maintenance

Specific service tasks required after the first 50 hours of operation.

Every 100 Hours Maintenance

Periodic maintenance tasks to be performed every 100 operating hours.

Every 250 Hours Maintenance

Periodic maintenance tasks to be performed every 250 operating hours.

Every 500 Hours Maintenance

Periodic maintenance tasks to be performed every 500 operating hours.

Every 1000 Hours Maintenance

Periodic maintenance tasks to be performed every 1000 operating hours.

Troubleshooting

Generator Troubleshooting Guide

Common generator issues and their potential causes and solutions.

Engine Starting Difficulties

Diagnosing and resolving problems when the engine won't start.

Starter Not Responding Issues

Troubleshooting when the starter motor fails to engage.

Insufficient Power Output

Identifying reasons for reduced generator power generation.

Sudden Engine Stoppage

Causes and solutions for the engine stopping unexpectedly.

Excessive Black Exhaust Smoke

Diagnosing issues related to abnormal exhaust smoke color.

Immediate Engine Shutdown Conditions

Recognizing and responding to critical engine operating states.

Engine Overheating Causes

Troubleshooting steps for an overheating engine.

Wiring Diagrams

Engine Circuit Diagrams

Electrical schematics detailing engine control and sensor circuits.

Generator Circuit Diagrams

Electrical schematics for generator output, AVR, and control circuits.

Danger, Warning, and Caution Labels

Label Care and Maintenance

Guidelines for keeping safety labels clean, legible, and properly affixed.

Operation and Inspection of the Emergency Relay

Emergency Relay Alarms and Corrections

Understanding indicator lamps and corrective actions for safety system faults.

Kubota KJ-S130VX Specifications

General IconGeneral
Voltage (V)230
Frequency (Hz)50
FuelDiesel
Max Output (kVA)13
Engine TypeWater-cooled, 4-cycle diesel
Noise Level68 dB(A)