G-14
V3-E3B SERIES, V3-E3CB SERIES, V3-E3BG SERIES, WSM
G GENERAL
Checking Battery Electrolyte Level
1. Check the battery electrolyte level.
2. If the level is below than lower level line (2), and the distilled water
to pour level of each cell.
W1047154
Checking Intake Air Line
1. Check to see if the intake air hose(s) are properly fixed every 250
hours of operation.
2. If the clamp is loose, apply oil to the threads and retighten it
securely.
3. The intake air hose(s) is made of rubber and tends to age. It must
be change every two years. Also change the clamp and tighten
it securely.
• To prevent serious damage to the engine, keep out any dust
inside the intake air line.
W1029631
[5] CHECK POINTS OF EVERY 500 HOURS
Changing Engine Oil
[V3800DI-T-E3B, V3800DI-T-E3CB, V3800DI-T-E3BG]
• Be sure to stop engine before changing engine oil.
1. Start and warm up the engine for approx. 5 minutes.
2. Place an oil pan underneath the engine.
3. To drain the used oil, remove the drain plug (1) at the bottom of
the engine and drain the oil completely.
4. Screw the drain plug (1).
5. Fill new oil up to upper line on the dipstick (2).
• When using an oil of different maker or viscosity from the
previous one, drain all of the old oil.
• Never mix two different types of oil.
• Engine oil should have properties of API classification CF
(See page G-7).
• Use the proper SAE Engine Oil according to ambient
temperature.
W1027890
(1) Upper Level Line (2) Lower Level Line
(1) Intake Air Hose (2) Clamp
Above 25 °C (77 °F)
SAE 30 or SAE 10W-30
SAE 10W-40
0 °C to 25 °C (32 °F to 77 °F)
SAE 20 or SAE 10W-30
SAE 10W-40
Below 0 °C (32 °F)
SAE 10W or SAE 10W-30
SAE 10W-40
Engine oil capacity
13.2 L
3.49 U.S.gals
(1) Drain Plug (2) Dipstick