SECTION 4
4.3.2
4.3.3
4.4
4.4.1
4.4.2
batteries
should
be
replaced
within
a
couple
of
weeks
to
ensure
continued
safety
of
your
RAM
entries.
To
replace
the
batteries,
turn
the
unit
over
on
a
soft
surface
and
remove
the
battery
compartment
cover
(see
Figure
4.1).
A
small
tool,
such
as
a
screwdriver,
may
be
n'ecessary
in
unlatching
the
tab.
Be
careful
not
to
break
this
tab.
Replace
the
batteries
with
three
high
quality
AA
size
"heavy
duty"
or
alkaline
batteries.
A
capacitor
will
keep
the
memory
alive
for
about
30
seconds
while
changing
the
batteries,
thus
do
not
remove
the
old
Figure
4.1
-
Battery
positioning
ones
until
the
new
ones
are
ready
for
installation.
Alternatively,
it
is
permissible
to
the
power
cable
plugged
in
and
the
power
on
while
changing
the
batteries,
in
which
case
memory
will
be
retained
as
long
as
power
is
on.
Be
sure
to
insert
the
new
batteries
in
the
directions
indicated
by
markings
in
the
bottom
of
the
battery
compartment.
Incorrect
insertion
won't
damage
anything
but
the
memory
won't
receive
any
power
from
the
batteries.
Most
quality
brand-name
batteries
now
have
"sell
by"
dates
printed
on
their
packages.
Carbon-zinc
batteries
will
last
for
at
least
a
year
after
installation
while
alkaline
batteries
should
last
for
at
least
2
years
provided
they
are
installed
before
the
date
on
the
package.
Rechargeable
batteries
should
not
be
used;
the
K2000
will
not
recharge
them
and
their
life
after
charging
on
an
external
charger
will
be
only
a
few
months.
Battery
life
is
not
significantly
increased
by
leaving
your
K2000
on
all
the
time;
batteries
may
even
suffer
heat
degradation
if
the
K2000
is
left
on
continuously.
USER
CALLABLE
DIAGNOSTICS
If
difficulty
is
experiences
with
a
third-party
switch
pedal
or
control
pedal,
the
built-in
user
callable
diagnostic
program
may
help
in
diagnosing
the
problem.
This
program
will
display
on
the
LCD
exactly
what
the
K2000's
internal
computer
sees
when
the
pedal
is
used.
This
can
help
determine
if
there
really
is
a
physical
problem
with
the
pedal
or
merely
a
programming
problem
in
your
program
or
setup.
The
diagnostic
can
be
used
to
check
out
the
keyboard
and
built-in
controls
as
well.
To
enter
the
diagnostic
program,
simply
press
the
buttons
simultaneously
when
in
the
Program
Mode.
respond
by
lighting
each
LED
in
sequence
and
then
following
on
the
LCD:
K2061
SCANNER
DIAGNOSTICS VERSION
1.4
(PRESS "EXIT"
AND
"ENTER"
TO
EXIT)
BATTERY-4.5 VOLTS,
WHEEL
CENTER-128
2
4,
5,
and
6
The
K2000
will
displaying
the

Related product manuals