Chapter
2
Diagnostics
Entering
Diagnostics
Important:
All
user
setups
should
be
saved
prior
to
entering
any
diagnostic
mode.
If
you
have
a
sequencer
or
computer,
you
should
save
the
customer's
setups
so
that
they
can
be
reloaded
after
the
Diagnostic
Tests
are
exited.
Press
the
Global
button
to
enter
the
Global
menu
and
step
through
the
selections
until
you
reach
Dump
all
Setups?
Select
Enter.
To
enter
the
PC88
Diagnostics,
apply
power
to
the
PC88
while
simultaneously
holding
down
the
1,2
and
3
buttons.
As
soon
as
power
is
applied,
immediately
release
the
1,2
and
3
buttons.
Continuing
to
depress
the
buttons
may
cause
the
unit
to
simply
sit
there
with
a
blank
screen.
You
should
see
the
following
in
the
LCD.
a
Press
<<<
to
Reset..
Press
>>>
for
Diags.
Press
the
>>>
button,
which
will
enter
diagnostics.
PC88
Service
Manual
2-2