7 Troubleshooting
This section is intended to provide a simple means of determining if a problem exists in
the KVH DSP-3000 gyro and assumes that the unit has passed the bench testing described
in previous sections.
The DSP-3000 is supplied as a sealed unit. Breaking the QA
seals voids the warranty and may violate the contract under
which the unit was supplied.
The warranty does not apply if the unit has been damaged by
misuse or as the result of service or modification other than by
KVH Industries.
Table 10: Troubleshooting
Symptom Possible Cause Action
No DC power Check power (measure power
at the gyro)
No output
Bad cable Check cable and terminal
emulation setup (no control
signal)
BIT line level (pin 8)
is TTL High
Internal fault Replace gyro
Faulty ground Ground shield at gyro end only Erratic or low output
Magnetic field near gyro Check for new wiring or
equipment
High noise Ground loop Check grounds and grounding
Technical Support
For technical support, please e-mail your question or a description of your problem to
fogsupport@kvh.com.