EasyManuals Logo

KYORITSU KEW 4106 User Manual

KYORITSU KEW 4106
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #12 background imageLoading...
Page #12 background image
8
●MeasuringmethodforEarthResistance
  
Fall-of-potentialmethod(currentsandvoltagesmeasuredviatheProbes)
●MeasurementmethodofEarthResistivity(ρ)
  Wenner4-polemethod
●OutputCharacteristics
  MeasuringVoltageUm (max.) approx 10Vrms 94Hz, 105Hz, 111Hz,
128Hz
  MeasuringCurrentIm (max.)approx80mA,however,Im×(Re+Rh)
<Um
●MeasuringMethodforSeriesInterferenceVoltage(earthvoltage)
  RMSRectifier(betweentheE-STerminals)
●MemoryCapacity:800data
●CommunicationInterface :Model8212USBOpticalAdaptor
●LCD Dot-matrix192×64,monochrome
Backlight
Earthresistance :max209.9kΩ
Earthresistivity :1999kΩ・m
SeriesInterferenceVoltage :max50.9V
●LowBatteryWarning :Batterymarkappears.
●ContinuousMeasurement :400timesormorewithmanganesebatteries;
repeating measurements at every 30 sec
withaloadof1Ωat2ΩRange.
●Over-rangeIndication :OL
●Auto-Power-Off :automatically powered off when 5 min
passeswithoutanyKeyoperation.
●Locationforuse :
Indoor/Outdooruse(Notcompletelywaterproof),
altitude2000morless
●Applicablerange :
Testingearthresistanceonpowerdistribution
lines, in-house wiring system and electrical
appliances
●Temperature&Humidityrange(guaranteedaccuracy):
  23℃±5℃ ,relativehumidity85%orless(nocondensation)
●OperatingTemperature&Humidityrange:
  -10℃
~
50℃ ,relativehumidity75%orless(nocondensation)
●StorageTemperature&Humidityrange:
  -20℃
˜
60℃ ,relativehumidity75%orless(nocondensation)
●OverloadProtection:betweenE-S(P)andbetweenE-H(C)terminals
  AC280V/10sec
●WithstandVoltage :betweentheelectricalcircuitandenclosure
AC3540V(50/60Hz)/5sec
●InsulationResistance :betweentheelectricalcircuitandenclosure
50MΩormore/DC1000V