KYORITSU KEW SNAP Series KEW2040 User Manual

KYORITSU KEW SNAP Series KEW2040
4 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
INSTRUCTIONMANUAL
DIGITALCLAMPMETER
KEWSNAP
SERIES
KEW2040
 
600AACOnlyType
KEW2055
1000AAC/DCType
Features
Designedtomeetinternationalsafetystandards.
IEC61010-1.IEC61010-031:2002&IEC61010-2-032
MeasurementCategory(CAT.)IV600V
PollutionDegree2
Double molded main body provides comfortable
singlehandedgrip
DataHoldFunction
LCD Backlight function to facilitate working at
dimlylitsituations.(KEW2055only)
RELfunctiontoindicatemeasurementvariation.
(Current,voltage,Resistancemeasurement)
MIN/MAX function enables easy reading of min &
maxvalueduringmeasurement.
WithContinuity&DiodeCheckFunction
NCV
Non Contact Voltage
Function for wiring
check.
600Vinputprotection.
Sleepfunctiontoextendbatterylife.
WithBarGraph,6039counts
2.SafetyWarnings
This instrument has been designed, manufactured and
testedaccordingtoIEC61010:Safetyrequirementsfor
Electronic Measuring apparatus, and delivered in
the best condition after passed the inspection. This
instruction manual contains warnings and safety
rules which must be observed by the user to ensure
safeoperationoftheinstrumentand retain it in safe
condition.
Therefore, read through these operating instructions
beforeusingtheinstrument.
WARNING
Read through and understand the instructions
contained in this manual before using the
instrument.
Keep the manual at hand to enable quick
referencewhenevernecessary.
Theinstrumentistobeusedonlyinitsintended
applications.
Understa n d a n d f o l l o w a l l t h e s a f e t y
instructionscontainedinthemanual.
It is essential that the above instructions are
adheredto.
Failure to follow the above instructions may
causeinjury,instrumentdamageand/ordamage
toequipmentundertest.
Thesymbol
indicatedontheinstrumentmeans that
theusermustrefertotherelatedpartsinthemanual
forsafeoperationof the instrument.Itisessential to
read the instructions wherever the
symbol appears
inthemanual.

DANGERisreservedforconditions andactions
thatarelikelytocauseseriousorfatalinjury.

WARNINGisreservedforconditionsandactions
thatcancauseseriousorfatalinjury.

CAUTIONisreservedforconditionsandactions
thatcancauseinjuryorinstrumentdamage.
Marks listed in the table below are used on this
instrument.
Usermustrefertothemanual.
Instrumentwithdoubleorreinforcedinsulation
Indicates that this instrument can clamp on
bare conductors when measuring a voltage
corresponding to the applicable measurement
category,whichismarkednexttothissymbol.
AC
DC
AC&DC
DANGER
Nevermakemeasurementonacircuitinwhich
voltageoverAC600Vexists.
Do not attempt to make measurement in the
presence of flammable gasses. Otherwise, the
use of the instrument may cause sparking,
whichcanleadtoanexplosion.
Transformerjawtipsare designednot toshort
the circuit under test. If equipment under test
has exposed conductive parts, however, extra
precaution should be taken to minimize the
possibilityofshorting.
Never attempt to use the instrument if its
surfaceoryourhandiswet.
Donotexceedthemaximumallowableinputof
anymeasuringrange.
Never o pen t he Bat ter y cov er d uri ng a
measurement.
Theinstrumentistobeusedonlyinitsintended
applications or conditions. Otherwise, safety
functions equipped with the instrument doesn
t
work,andinstrumentdamageorseriouspersonal
injurymaybecaused.
WARNING
Never attempt to make measurement if any
abnormal conditions, such as broken case
and exposed metal parts are found on the
instrument.
Do not rotate the Function Switch while the
testleadsarebeingconnected.
Do not install substitute parts or make any
modification to the instrument. For repair or
re-calibration, return the instrument to your
localdistributorfromwhereitwaspurchased.
Do not try to replace the batteries if the
surfaceoftheinstrumentiswet.
Disconnect all the cords and cables from the
objectundertestandpowerofftheinstrument
before opening the Battery Cover for Battery
replacement.
Verify proper operation on a known source
before use or taking action as a result of the
indicationoftheinstrument.
Use appropriate personal protective equipment
suchasinsulatinggloves,Insulatingboots,and
safetyglasses.
CAUTION
Set the Function Switch to an appropriate
positionbeforestartingmeasurement.
Firmlyinsertthetestleads.
Disconnect the test leads from the instrument
forcurrentmeasurement.
Donotexposethe instrumenttothedirectsun,
hightemperatureandhumidityordewfall.
Altitude 2000m or less. Appropriate operating
temperatureiswithin0
and40
.
Thisinstrumentisn
tdust&waterproofed.Keep
awayfromdustandwater.
Be sure to power off the instrument after use.
When the instrument will not be in use for a
longperiod,placeitinstorageafter removing
thebatteries.
U se a c lot h dip ped in w ate r o r neu tra l
detergent for cleaning the instrument. Do not
useabrasivesorsolvents.
Measurementcategories
(Over-voltagecategories)
To ensure safe operation of measuring instruments,
IEC61010 establishes safety standards for various
electrical environments, categorized as CAT.I to
CAT.IV, and called measurement categories. Higher-
nu mbered c at egories co rrespond to e le ctrical
environment s with grea ter momentary energy ,
so a measuring instrument designed for CAT.III
environments can endure greater momentary energy
thanonedesignedforCAT.II.
CAT.Ⅰ
:Secondary electricalcircuitsconnectedtoan
ACelectricaloutletthroughatransformeror
similardevice.
CAT.Ⅱ
:Primary electrical circuits of equipment
connected to an AC electrical outlet by a
powercord.
CAT.Ⅲ
:Primary electrical circuits of the equipment
connected directly to the distribution panel,
and feeders from the distribution panel to
outlets.
CAT.Ⅳ
:The circuit from the service drop to the
service entrance, and to the power meter
and primary over current protection device
(distributionpanel).
3.Specification
3-1.Measuringrange&accuracy
(accuracyguaranteedat23
℃±
5
.humidity45
85%)
ACCurrent600A,1000AFunction
Function
Measuring
Range
Accuracy
KEW2040 KEW2055
600A 0-600.0A
±
1.5%rdg
±
5dgt
(50/60Hz)
±
3.5%rdg
±
8dgt
(40-400Hz)
±
1.5%rdg
±
5dgt
(50/60Hz)
±
3.5%rdg
±
8dgt
(40-400Hz)
1000A 0-1000A
N/A
DCCurrent600A,1000AFunction
Function
Measuring
Range
Accuracy
KEW2040 KEW2055
600A
0-600.0A
N/A
±
1.5%rdg
±
5dgt
1000A
0-1000A
N/A
ACVoltageFunction

Auto-ranging,Inputimpedance:approx.10M
Ω
Range
Measuring
Range
Accuracy
KEW2040 KEW2055
6/60/600V 1-600.0V
±
1.3%rdg
±
4dgt(50/60Hz)
±
3.0%rdg
±
5dgt(40
400Hz)
DCVoltageFunction

Auto-ranging,Inputimpedance:approx.10M
Ω
Range
Measuring
Range
Accuracy
KEW2040 KEW2055
600mV/6/
60/600V
0-600.0V
±
1.0%rdg
±
3dgt
Resistance
Continuity/DiodeCheck
Function
Range
Measuring
Range
Accuracy
KEW2040 KEW2055
600
Ω
/6k/
60k/600k
Ω
6M
Ω
0-6M
Ω
±
1.0%rdg
±
5dgt
60M
Ω
6.00M-
60.00M
Ω
±
5%rdg
±
8dgt
ContBuzzer 0-600.0
Ω
Thresholdvalue:60
Ω±
30
Ω
Diode
Testvoltage:0-2V
Frequ enc y/ D UTY F uncti on
Auto- ran gin g f or
Frequency
Range
Measuring
Range
Accuracy
KEW2040 KEW2055
ACA 40Hz
400Hz
±
0.5%rdg
±
5dgt
ACV 1Hz
10kHz
0.1-99.9%
(Pulsewidth/Pulseperiod)
±
2.5%rdg
±
5dgt
Note:Measurableinputsare:40Vrms@ACVor
60Arms@AC600A,350A@AC1000ARange
3-2.GeneralSpecification
Modeofoperation
:
Δ
∑mode
Display
:max.6039counts

     
(Frequency:9999)&Bargraph
Over-range indication : "OL" displayed when exceeding
the measuring range. (except for AC/DCV and 1000A
Function)
Rangeswitching :
Auto-ranging/Voltage,ResistanceRange
Singlerange/Continuity,Diodecheckand
DUTY
Samplerate
  
:threetimespersecond
Functionalconstruction:
OFF/ACA/ACV/DCV/
Ω
KEW2040
OFF/ACA/DCA/ACV/DCV/
Ω
KEW2055
Keys :
SELECT(AC/DCswitching&/
Ω
/ / ),REL
Δ
,
Hz/DUTY,MIN/MAX,HOLD/BackLight(KEW2055)
Powersource :DC3V/R03(UM-4)x2pcs
Lowbatterywarning
:
" "markisdisplayedat
   
2.4V
±
0.15Vorless.
Temperature & humidity : 23
℃±
5
, relative humidity
accuracyguaranteed85%orless(nocondensation)
Operatingtemperature:0
40
,relativehumidity
&humidityrange85%orless(nocondensation)
Storagetemperature :-20
60
,relativehumidity
&humidityrange85%orless(nocondensation)
Currentconsumption:approx.12mA
SleepFunction:Automaticallypoweredoffinabout
15minafterthelastFunctionswitchoperation.
Press any key or rotate the Function Switch from
OFFtoanypositiontoexitfromtheSleepstate.
ApplicableStandards
IEC61010-1:2001
MeasurementCAT.IV600VPollutiondegree2
IEC61010-031:2002,IEC61010-2-032
EMC
EN61326
EN55022
EN61000-4-2(performancecriterionB)
EN61000-4-3(performancecriterionB)
OverloadProtection
CurrentRange :720AAC/10sec@KEW2040
1200AAC/DC/10sec@KEW2055
VoltageRange :720VAC/DC/10sec
ResistanceRange :600VAC/DC/10sec
WithstandVoltage
6880VAC
TRMS50/60Hz
/5sec
(betweenJawsandelectricalcircuit/betweeninternal
circuitandenclosure)
InsulationResistance:10M
Ω
ormore/1000V
betweenelectricalcircuitandenclosure
Conductorsize
KEW2040:approx.33mm
KEW2055:approx.40mm
Dimension
approx.254(L)
×
82(W)
×
36(D)mm/KEW2055
approx.243(L)
×
77(W)
×
36(D)mm/KEW2040
Weight:approx.:300g@KEW2040
:310g@KEW2055
Accessories
TestLeads Model7066/1set
BatteryR03
UM-4
/2pcs
InstructionmanualEnglish,Japanese/1pce
CarriyngCaseModel9094/1pcs
3-3.FunctionKeys
The"
"markshowsavailablefunctionateachRange.
DCCurrentMeasurement(KEW2055only)
HOLD SELECT ZERO
Hz/
DUTY
MAX/
MIN
ACA
ACV
-
DCA
-
DCV
-
-
Ω
-
-
- - -
-
- - -
4.Preparationformeasurement
4-1.CheckingBatteryVoltage
Set the Function Switch to any position other than
"
OFF
".Whenthedisplay isclearwithout"
BATT
"mark,
showing, battery voltage is enough. When the display
is blank or
"
BATT
" mark is indicated, replace the
batteriesaccordingtoSection7,BatteryReplacement.
CAUTION
The Sleep feature automatically powers the
instrument off in about 15 min after the last
switch or key operation. Therefore, the display
may beblankevenwiththeFunctionSwitchset
to a position other than "
OFF
". To operate the
instrument in this case, turn the switch back to
the "
OFF
" position, then to any other position,
orpressanykey.Replacethebatteriesifnothing
wasdisplayedafteraboveoperations.
4-2.CheckingSwitchSetting&Operation
Confirm the Function Switch is set to the correct
posit ion , t he i nst rumen t i s set to the c orrec t
measurementmode,
and the Data hold function is disabled. Otherwise,
desiredmeasurementcannotbemade.
5.Measurement
5-1.ACCurrentMeasurement
DANGER
Never make measurementon a circuitin which
voltage over AC600V exists to avoid getting
electricalshock.
Transformer jaw tips are designed not to short
the circuit under test. If equipment under test
has exposed conductive parts, however, extra
precaution should be taken to minimize the
possibilityofshorting.
Do not make measurement with the Battery
Coverremoved.
Disconnectthetestleadsfromtheinstrumentfor
currentmeasurement.
(1)Set the Function Switch to "
600A
" or "
1000A
"
position.(onKEW2040,only"600A"isavailable)
AChasbeenselectedbydefault;presstheSELECT
key, when DC has been selected, to change it to
AC.ACmark is displayed attheupper left onthe
display.(KEW2055only)
(2)Press the trigger to open the transformer jaws
andclampthemontotheoneconductorundertest,
then take the reading on the display. Pressing the
"
Hz/DUTY
"Keyswitchestheindicationinfollowing
sequence.
ACCurrent
Hz
DUTY
Hz/DUTY
Function requires 60A or more at AC600A
Rangeand350AormoreatAC1000Arange.
CAUTION
MaxconductorsizeforKEW2040isapproxdia.
33mm and for KEW2055 is approx dia. 40mm.
During current measurement, keep the trans
former jaws fully closed. Other wise, accurate
measurementscannotbetaken.
5-2.DCCurrentMeasurement(KEW2055only)
DANGER
Nevermakemeasurementonacircuitinwhich
voltage over DC600V exists to avoid getting
electricalshock.
Do not make measurement with the Battery
Coverremoved.
(1)Set the Function Switch to "
600A
" or "
1000A
"
position. AC has been selected by default; press
the SELECT key, when AC has been selected, to
changeittoDC.
DC mark is displayed at the upper left on the
Transformer

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KYORITSU KEW SNAP Series KEW2040 and is the answer not in the manual?

KYORITSU KEW SNAP Series KEW2040 Specifications

General IconGeneral
BrandKYORITSU
ModelKEW SNAP Series KEW2040
CategoryMultimeter
LanguageEnglish

Related product manuals