ENCLOSURE CHECK
technical bulletin
ENCLOSURE-CHECK_TB_EN_1.0 l-acoustics.com 4 / 5
RESULTS
Five different results can be displayed for each output: OK,?, NC, NOK and UNDEF.
Table 1: Interpreting the results
measured impedance is within expected range
Enclosure is in working order electrically
unsupported preset family
Only supported enclosures should be tested
1. Inspect the cables and connections
If necessary, replace the cables and repeat
the check.
2. Hold the OUT key for details and open the
enclosure for investigation.
measured impedance is not within expected range
1. Check that all the requirements are met
(see section REQUIREMENTS).
Check in particular that the loaded preset
corresponds to the connected loudspeaker’s
family.
2. Inspect the cables and the connections
If necessary, replace the cables and repeat
the check.
3. Hold the OUT key for details and open the
enclosure for investigation.
measured impedance is undefined
Under NC, NOK and UNDEF results, press and hold the OUT key to display the tested frequencies, details on the
measured impedance, and the number of operational transducers out of the total.
Details on the measured impedance can be:
OPEN for open circuit (found in NC results)
SHORT for short circuit (found in NOK results)
a percentage of variation from the expected range (found in NOK and UNDEF results)
Once the causes for short circuits and unexpected open circuits are identified and fixed, repeat the check.