Ordering Replacement Parts
Contact La Marche to place an order for spare or replacement parts. To order replacement parts; please provide
the model and serial number of the battery inverter, the parts needed, and the quantity required.
SCR Modules
The procedure for checking the SCR module is as follows:
Disconnect the wiring going to the module.
Using an ohmmeter, the three main terminals (A1K2, K1, A2) you should read high resistance in both
directions on your meter.
Gate (G1) should read a high resistance between the top (A1K2), bottom (A2) terminals and a low resistance
(10 Ohm - 40 Ohm) to the middle (K1) terminal.
Gate (G2) should read a high resistance between the middle (K1) and (A2) terminal and a low resistance
between terminal (A1K2).
NOTE: A wiring diagram of the module is located on the side of the component.
IGBT Modules
With an ohmmeter, measure the resistance between Terminal 1 (collector) and Terminal 2 (emitter) negative
lead on Terminal 1 should read, low resistance. Reverse the meter leads and it should read a high resistance.
With negative lead on one, measure to Terminal 3, it should read high resistance.
With negative lead on Terminal 1, measure to Terminal 5, it should read a low resistance.
When the S2A-297 or S2A-306 card is removed, jump the gate and emitter of the IGBT with copper wire to
protect from ESD damage.
C1, Resonating Capacitors 560 VAC 660 VAC (approximately)
With an ohmmeter, the meter should deflect to low resistance, then gradually rise to high resistance.